Adda-10l fault arc break detector front:
With the development of national economy The power consumption of exhibition, production and residents is increasing day by day, and the occurrence of electrical fire accidents is also increasing day by day
How to effectively detect electricity The causes of gas fire, reducing the incidence of electrical fire accidents and the loss of life and property have become the research focus of safe power consumption
In the low-voltage distribution system of buildings, the existing prevention of electrical fire
The disaster protection device mainly detects the overcurrent caused by overload and short circuit and the residual current caused by grounding fault
When the series fault arc that is easy to cause electrical fire occurs, because the fault current value is lower than the action threshold of traditional protection devices, it can not comprehensively and effectively prevent electrical fire
As a result, the fire caused by electrical fault in China ranks first among the fires caused by other reasons every year
The development status of fault arc detection technology is analyzed, and the key problems to be solved in fault arc detection are analyzed
Secondly, in order to analyze the characteristics of fault arc, an experimental platform for simulating fault arc in low-voltage distribution line is built
The current transformer is used to collect the fault arc current waveform during loop load transformation, and simulate the fault arc under resistive load, inductive load and resistive inductive load respectively
Through a large number of fault arc experiments, the typical characteristics of fault arc can be extracted
Then the wavelet analysis theory is applied to the diagnosis of fault arc
Thirdly, the system uses wavelet analysis as a tool to judge whether fault arc occurs by detecting whether there are periodic singularity points in the current signal
The system selects and constructs the orthogonal quadratic spline wavelet as the wavelet function, and uses the wavelet approximation method to analyze the current signal
In 2016, our team took the lead in successfully developing practical adda-10l fault arc breaking detector technology in China
It has complete domestic intellectual property rights and is particularly suitable for China's power grid conditions
At present, it is at the leading level in China
It can be predicted that in the near future, all low-voltage electrical lines and household appliances at home and abroad will actively adopt mature and reliable fault arc protection technology (device) & mdash& mdash; Just like using short-circuit protector, overload protector and leakage protector, it has become the basic equipment in the field of low-voltage power grid and electrical safety
Product features
This product is adda-10l fault arc detector, which complies with the national standard GB14287
4-2014, this product can effectively detect adda-10l fault arc (including fault parallel arc and fault series arc) in the access line
When the fault arc causing fire is detected in the line, it can carry out on-site audible and visual alarm, and transmit the alarm information to the upper monitoring equipment, so as to realize the purpose of early warning fire
This product is adda-10l fault arc detector, which complies with the national standard GB14287
4-2014, the product can effectively detect adda-10l fault arc (including fault parallel arc and fault series arc) in the access line
When the fault arc causing fire is detected in the line, it can carry out on-site audible and visual alarm, and transmit the alarm information to the upper monitoring equipment, so as to realize the purpose of early warning of fire
2
Technical parameters of ADDA fault arc breaking detector:
Model: adda-16, adda-32, adda-16l, adda-25l
Rated current range of protection line: adda-16: 1 ~ 16a, adda-32: 0 ~ 32a, adda-16l: 0 ~ 16a, adda-25l: 0 ~ 32A
Display: Adda-16: nixie tube display, Adda-32: nixie tube display, , Adda-16l: liquid crystal display, adda-25l: liquid crystal display
Rated working voltage: AC220V
Labor consumption: ≤ 2
5W
Local fault prompt: acoustooptic signal
Fault action time: ≤ 0
5
Control output: adda-16, adda-32a: no mechanical normally open contact
Adda-16l and adda-25l: 1 set of mechanical normally open contacts, contact capacity: AC 250V / 5A, DC 24V / 15A
Communication: RS485
Installation method: Standard 35mm guide rail installation
Operating environment: relative humidity: ≤ 96%, ambient temperature: - 10 ℃ ~ 40 ℃
Product executive standard: gb14287 4-2014
ADDA fault arc break detector model:
ADDA fault arc break detector size:
Instructions for ADDA fault arc break detector:
ADDA fault arc break detector manufacturer:
Knowledge of ADDA fault arc break detector:
Application knowledge of ADDA fault arc break detector:
Technical parameters of ADDA fault arc breaking detector:
Necessity of ADDA fault arc break detector products:
Model selection manual of ADDA fault arc break detector:
What's up? Baby Post & ldquo; Don't contaminate the unsuitable Circle & rdquo; Seems to have deep meaning
premiumexporter.com温馨提示
本网页所展示的有关【Adda-10l fault arc detector manufactured by Jiaxing】的信息/图片/参数等由的会员【Yueqing Jiaxing Electric Appliance Co., Ltd】提供,由premiumexporter.com会员【Yueqing Jiaxing Electric Appliance Co., Ltd
】自行对信息/图片/参数等的真实性、准确性和合法性负责,本平台(本网站)仅提供展示服务,请谨慎交易,因交易而产生的法律关系及法律纠纷由您自行协商解决,本平台(本网站)对此不承担任何责任。您在本网页可以浏览【Adda-10l fault arc detector manufactured by Jiaxing】有关的信息/图片/价格等及提供【Adda-10l fault arc detector manufactured by Jiaxing】的商家公司简介、联系方式等信息。
在您的合法权益受到侵害时,请您致电,我们将竭诚为您服务,感谢您对premiumexporter.com的关注与支持!