& Nbsp& Nbsp& Nbsp; Cka10-40l fault arc detector manufactured by Jiaxing ,& Nbsp; Manual double throw disconnector, double power automatic transfer switch, control and protection switch, AC contactor 1
Front of cka10-40l fault arc breaking detector: with the development of national economy, the power consumption of production and residents is increasing, and the occurrence of electrical fire accidents is also increasing
How to effectively detect the causes of electrical fire and reduce the incidence of electrical fire accidents and the loss of life and property has become the research focus of safe power consumption
In the low-voltage distribution system of buildings, the existing protection devices for preventing electrical fire mainly detect the overcurrent caused by overload and short circuit and the residual current caused by grounding fault
When the series fault arc that is easy to cause electrical fire occurs, because the fault current value is lower than the action threshold of traditional protection devices, it can not comprehensively and effectively prevent electrical fire
As a result, the fire caused by electrical fault in China ranks first among the fires caused by other reasons every year
The development status of fault arc detection technology is analyzed, and the key problems to be solved in fault arc detection are analyzed
Secondly, in order to analyze the characteristics of fault arc, an experimental platform for simulating fault arc in low-voltage distribution line is built
The current transformer is used to collect the fault arc current waveform during loop load transformation, and simulate the fault arc under resistive load, inductive load and resistive inductive load respectively
Through a large number of fault arc experiments, the typical characteristics of fault arc can be extracted
Then the wavelet analysis theory is applied to the diagnosis of fault arc
Thirdly, the system uses wavelet analysis as a tool to judge whether fault arc occurs by detecting whether there are periodic singularity points in the current signal
The system selects and constructs the orthogonal quadratic spline wavelet as the wavelet function and uses the wavelet approximation method to carry out the current signal
In 2016, our team took the lead in successfully developing the practical cka10-40l fault arc breaking detector technology in China
It has complete domestic intellectual property rights and is particularly suitable for the national conditions of China's power grid
At present, it is at the leading level in China& Nbsp; It can be predicted that in the near future, all low-voltage electrical lines and household appliances at home and abroad will actively adopt mature and reliable fault arc protection technology (device) & mdash& mdash; Just like using short-circuit protector, overload protector and leakage protector, it has become the basic equipment in the field of low-voltage power grid and electrical safety& Nbsp; Product features ,& Nbsp& Nbsp This product is cka10-40l fault arc detector, which complies with the national standard gb14287 4-2014, this product can effectively detect the cka10-40l fault arc (including fault parallel arc and fault series arc) in the access line
When the fault arc causing fire is detected in the line, it can carry out on-site audible and visual alarm, and transmit the alarm information to the upper monitoring equipment, so as to realize the purpose of early warning of fire& Nbsp& Nbsp& Nbsp This product is cka10-40l fault arc detector, which complies with the national standard gb14287 4-2014, the product can effectively detect the cka10-40l fault arc (including fault parallel arc and fault series arc) in the access line
When the fault arc causing fire is detected in the line, it can carry out on-site audible and visual alarm, and transmit the alarm information to the upper monitoring equipment to achieve the purpose of early warning of fire 2
Technical parameters of cka10 fault arc break detector: model: cka10-16, cka10-32, cka10-16l, cka10-25l rated current range of protection line: cka10-16:1 ~ 16a, cka10-32:0 ~ 32a, cka10-16l:0 ~ 16a, cka10-25l:0 ~ 32A display: Cka10-16: nixie tube display, cka10-32: nixie tube display, ,& Nbsp& Nbsp& Nbsp& Nbsp Cka10-16l: liquid crystal display, cka10-25l: liquid crystal display, rated working voltage: AC220V, labor consumption: ≤ 2
5W, local fault prompt: acousto-optic signal fault action time: ≤ 0
5, control output: cka10-16, cka10-32a: no mechanical normally open contact
Cka10-16l and cka10-25l: 1 set of mechanical normally open contacts, contact capacity: AC 250V / 5A, DC 24V / 15a, communication: RS485 installation method: Standard 35mm guide rail installation, operating environment: relative humidity: ≤ 96%, ambient temperature: - 10 ℃ ~ 40 ℃, product executive standard: gb14287 4-2014cka10 fault arc break detector model: cka10 fault arc break detector size: cka10 fault arc break detector specification: cka10 fault arc break detector manufacturer production: cka10 fault arc break detector Related Knowledge: cka10 fault arc break detector application knowledge: cka10 fault arc break detector technical parameters: necessity of cka10 fault arc break detector product: cka10 fault arc break detector selection manual data: The Ministry of foreign affairs responded to Zhang Yingying's case: it will continue to follow up the progress of the incident