1、 Overview
There will be various transient and transient overvoltage in various transmission and distribution systems
Due to the existence of this overvoltage, various overvoltage accidents will often occur, which will seriously endanger the 1 operation of primary equipment, especially dry insulation equipment such as rotating motors

Rotating electrical machines (generators, condenser, large motors, etc
) have some characteristics different from other primary equipment in terms of insulation structure, performance and insulation coordination

(1) In the electrical equipment with the same voltage level, the impact withstand voltage level of the insulation of rotating motor is low

The reasons are:
① The motor has a high-speed rotating rotor, so it can only use solid medium
In the manufacturing process, the solid medium is easy to be damaged and holes or gaps are easy to appear in the insulation
Therefore, partial discharge is easy to occur during operation, resulting in insulation deterioration;
② The operating conditions of motor insulation are the most severe, which is subject to the combined action of heat, mechanical vibration, moisture in the air, pollution, electromagnetic stress and other factors, and the aging speed is fast;
③ The electric field of the motor insulation structure is relatively uniform, and its impact coefficient is close to 1
Under overvoltage, its electrical strength is the weakest link
Therefore, the rated voltage and insulation level of the motor cannot be too high

(2)  Turn to turn insulation requires that the steepness of intrusive wave is strictly limited

  Because the inter turn capacitance of the motor winding is very small and discontinuous, the overvoltage wave can only propagate along the winding conductor after being forced into the motor winding, and the length of each turn of the winding is much longer than that of the transformer winding
The overvoltage acting between two adjacent turns is directly proportional to the steepness of the intrusion wave
Therefore, in order to protect the turn to turn insulation of motor, the steepness of intrusion wave must be strictly limited

Yhzrx capacitor overvoltage protection cabinet can absorb system energy, reduce overvoltage amplitude and limit system overvoltage; When the system has inductive load, it can not only limit the operating overvoltage to a certain range, but also delay the rise time of wave head of cut-off overvoltage and reignition overvoltage and reduce the steepness, so as to protect important electrical equipment, especially the turn to turn insulation of rotating motor
It can effectively limit the induced overvoltage and the impact of steep wave front on electrical equipment, and improve the power supply quality of power grid

2、 Scope of application
  Yhzrx capacitor absorption overvoltage protection cabinet is applicable to all kinds of factory power distribution, power generation and all kinds of power systems requiring rotating motor protection of 3
6 ~ 40
5 kV

3、 Working principle
Yhzrx capacitor absorption overvoltage protection cabinet adopts the combination of specially designed high-voltage protection capacitor and lightning arrester to delay the rise time of wave head of overvoltage and reburning overvoltage of current closure system, reduce the steepness of wave head, and protect primary equipment from the impact of steep wave front

4、 Product model and technical parameters
 
 
 
 
5、 Primary system diagram
 
6、 Structure, outline and installation dimensions
Standard size of the device: 6-10KV 800× 1500× 2300(KYN28-12)
  20KV 1000*1860*2370
  35KV 1400*2860*2600
  It can also be specially produced according to user requirements

 
 
 
 
 
 
 
 
 
 
7、 Service conditions
l  Ambient temperature: - 30 ℃ ~ + 60 ℃;
l  Atmospheric pressure: 80 ~ 110kpa;
l  Relative air temperature: 90% (25 ℃), 50% (40 ℃);
l  Altitude: & le; 1000m (altitude & Ge; it shall be indicated when ordering);
l  The installation low point shall be provided with wind, rain and sand prevention and dust prevention facilities;
l  There shall be no 1 dangerous medium in the place of use
The surrounding medium shall not contain conductive medium or gas that corrodes and destroys insulation
The environment shall not be filled with steam and contain serious mold

 
Contacts
Company Name
Anhui Yahui Electric Automation Co., Ltd
Name:
Mr. Lin Fei
Q Q
2880909601
Telephone
0551-63889111
Mobile
13349293555
Address
Operational Address
Building B-4, industrial investment Liheng industrial Plaza, bustling Avenue, Taohua Industrial Park, Hefei Economic Development Zone, Anhui Province
premiumexporter.com温馨提示

本网页所展示的有关【Yhzrx capacitor absorption cabinet】的信息/图片/参数等由的会员【Anhui Yahui Electric Automation Co., Ltd】提供,由premiumexporter.com会员【Anhui Yahui Electric Automation Co., Ltd 】自行对信息/图片/参数等的真实性、准确性和合法性负责,本平台(本网站)仅提供展示服务,请谨慎交易,因交易而产生的法律关系及法律纠纷由您自行协商解决,本平台(本网站)对此不承担任何责任。您在本网页可以浏览【Yhzrx capacitor absorption cabinet】有关的信息/图片/价格等及提供【Yhzrx capacitor absorption cabinet】的商家公司简介、联系方式等信息。

在您的合法权益受到侵害时,请您致电,我们将竭诚为您服务,感谢您对premiumexporter.com的关注与支持!