Welcome !

MCC Construction Research Institute (Shanghai) Co., Ltd

企业会员1YEAR

MCC Construction Research Institute (Shanghai) Co., Ltd

Country:Nationwide,China

Business:House quality inspection, house seismic evaluation, industrial building inspection and evaluation, glass curtain wall inspection, bridge inspection, engineer…

Shanghai industrial building reliability appraisal

PriceInquire

Quantity
Min. Order
0
Country
Shanghai,China
Recommended For You
the building quality inspection station of MCC Construction Research Institute (Shanghai) Co
, Ltd
has the Shanghai Grade a building quality inspection certificate and seismic identification certificate, and has the same relationship with the national industrial building diagnosis and reconstruction engineering technology research center of the General Institute, the national construction steel quality supervision and inspection center The inspection center of the metallurgical industry engineering quality supervision station and the national steel structure engineering technology research center share resources and personnel, and have a group of high-quality and experienced high and intermediate engineering and technical personnel and a series of advanced supporting technical equipment

  Our national construction steel quality supervision and inspection center is the only national quality inspection institution in the field of building materials authorized by the General Administration of quality supervision, inspection and Quarantine of the people's Republic of China, and has obtained certificates of national metrology certification (CMA), China Laboratory Accreditation (CNAL), and National Center Accreditation (CAL), http://www
chinajy-sh
com
cn/ Undertake the inspection and appraisal of construction steel, steel structure accessories, fiber materials and other products, and have the ability to arbitrate, consult and solve major technical and quality problems of construction steel

The national industrial building diagnosis and reconstruction engineering technology research center of our institute is the only national engineering technology research center in the field of civil building diagnosis and treatment technology
It has a group of high-quality and experienced middle-level engineering and technical personnel and a series of advanced supporting technical equipment
In the field of construction engineering quality inspection, reliability appraisal and evaluation of civil building structures, structural reinforcement, reconstruction and repair, high-efficiency prestressed engineering, nuclear power plant containment structure test and evaluation, large-scale engineering structure dynamic and static test and other construction technology control, and special repair materials for concrete structure durability protection, it is in the leading position in China

  In the field of building appraisal, diagnosis and reconstruction, our institute has the leading technical level in China, rich practical experience in appraisal and diagnosis engineering, profound appraisal and diagnosis theory and technology accumulation, a large number of experienced and dedicated inspection and appraisal personnel and a series of advanced supporting technical equipment, and has the ability to organize and implement the inspection and appraisal of large plants

  1、 The reliability evaluation of industrial buildings shall meet the following requirements:
  1
Reliability evaluation shall be carried out under the following circumstances;
  1) When it reaches the design service life and is intended to continue to be used;
  2) When the use or use environment changes;
  3) When carrying out reconstruction or capacity expansion, reconstruction or expansion;
  4) When suffering from disasters or accidents;
  5) There are serious quality defects or serious corrosion, damage and deformation

  2
Reliability evaluation should be carried out under the following circumstances:
  1) Routine inspection and identification are required during use and maintenance;
  2) When comprehensive and large-scale maintenance is required;
  3) Others need to master the structural reliability level

  3
When the structure has the following problems, which are only partial and do not affect the whole building and structure, special identification can be carried out as needed:
  1) When there are special requirements for the maintenance and transformation of the structure;
  2) When the durability damage of the structure affects its durability life;
  3) When the fatigue problem of the structure affects its fatigue life;
  4) When the structure has obvious vibration influence;
  5) When the structure needs long-term monitoring;
  6) When the structure is generally corroded or has other problems

  2、 The following work contents should be selected for the reliability appraisal and testing of industrial buildings according to the actual needs:
  1) Study relevant documents in detail

  2) Investigate in detail the role of the structure and adverse factors in the environment, as well as their possible changes within the target service life, and test the role or effect of the structure if necessary

  3) Check the structural layout and structure, support system, structural members and connections, and detect the defects and damages of the structure in detail, including the defects and damages of the bearing structure or members, support rods and their connecting nodes

  4) Check or measure the cracks, displacement or deformation of the load-bearing structure or member, and test the dynamic response and dynamic characteristics of the structure or member when there is a large dynamic load

  5) Investigate and measure the deformation of the foundation, and detect the impact of the foundation deformation on the upper load-bearing structure, enclosure structure system and crane operation
If necessary, the foundation can be excavated for inspection, and supplementary investigation or field load test can also be carried out

  6) Test the actual performance of structural materials and geometric parameters of components, and test the actual performance of structures or components through load tests if necessary

  7) Check the safety condition and use function of the enclosure system

  8) Reliability analysis and checking calculation should be based on the detailed investigation and testing results to analyze and check the reliability level of the whole and each component of buildings and structures, including structural analysis, structural or component safety and normal use verification analysis, cause analysis of existing problems, etc
In the reliability appraisal of industrial buildings, if the investigation and testing data are found to be insufficient or inaccurate, supplementary investigation and testing should be carried out in time

 

Contacts
Company Name
MCC Construction Research Institute (Shanghai) Co., Ltd
Name:
Ms. Miss Chen
Telephone
021-51870573
Address
Operational Address
Room 2110, floor 21, Ginza, Fortune International Plaza, No. 43, Guoquan Road, Yangpu District, Shanghai
Find Similar Products By Category
premiumexporter.com温馨提示

本网页所展示的有关【Shanghai industrial building reliability appraisal】的信息/图片/参数等由的会员【MCC Construction Research Institute (Shanghai) Co., Ltd】提供,由premiumexporter.com会员【MCC Construction Research Institute (Shanghai) Co., Ltd 】自行对信息/图片/参数等的真实性、准确性和合法性负责,本平台(本网站)仅提供展示服务,请谨慎交易,因交易而产生的法律关系及法律纠纷由您自行协商解决,本平台(本网站)对此不承担任何责任。您在本网页可以浏览【Shanghai industrial building reliability appraisal】有关的信息/图片/价格等及提供【Shanghai industrial building reliability appraisal】的商家公司简介、联系方式等信息。

在您的合法权益受到侵害时,请您致电,我们将竭诚为您服务,感谢您对premiumexporter.com的关注与支持!