brand: | Huicheng |
model: | HS -- 4 0 double cylinder |
concrete machinery type: | concrete mixing plant | theoretical conveying capacity of concrete: | 4, 0 (m3 / h) | / TR>
maximum outlet pressure of concrete: | 2,5 (MPA) |
rated feed capacity: | 4,0 (M3) |
rated discharge capacity: | 4, 0 (M3) |
hopper lifting speed: | 666 (M / min) |
maximum particle size of aggregate: | 0 15 (mm) |
Motor Power: | 4 (kw) |
unloading method: | self suction |
mixing power: | 560 (kw) | mixing drum speed: | 560 (min) |
mixing shaft speed: | 1400 (R / min) |
overall dimension: | 850600x900 (mm) |
machine weight: | 230 (kg) |
specification: | double cylinder grouting pump |
HS-4 double liquid grouting pump is a new generation of mortar conveying and slurry conveying pump product comprehensively developed by our factory for many years
This pump has the advantages of small volume, light weight, less work, large discharge volume, high working pressure without pulse, more stable operation, material saving, energy saving and convenient handling, It is your ideal mortar conveying equipment Main technical parameters of double cylinder double liquid grouting pump: Technical parameters: model HS-4 conveying capacity 4m3 maximum working pressure 4MPa main engine power 3kw motor speed 1440r / min slurry outlet pipe diameter 38mm slurry inlet pipe diameter 64mm mortar vertical conveying distance 50m machine weight 230kg The following matters should be paid attention to when using the grouting pump: 1
The transmission pipeline should have firm support, reduce bends as far as possible, connect all joints firmly, and do not pressurize or hang heavy objects on the pipeline
2
Before use, carry out idling, check that the rotation direction is correct, and the transmission part, working device and hopper filter screen are complete and reliable
3
Before use, pump the concentrated lime water or lime paste into the pipeline for lubrication
4
After starting, the mortar can be put into the pump only after the operation is normal
The mortar pump must operate continuously
When the mortar is not used for a short time, the return valve can be opened to make the mortar circulate in the pump body
If the shutdown time is long, it shall be pumped every 3 ~ 5min to make the mortar flow in the pipeline and pump body to prevent condensation and blockage
5
During work, always pay attention to the indication of the pressure gauge
If the specified pressure is exceeded, immediately find out the cause and eliminate the fault 6
Pay attention to check the wear of ball valve, valve seat or extrusion pipe
In case of slurry leakage, stop the machine for inspection, repair or replacement before continuing the operation
7
In case of fault shutdown, open the slurry discharge valve to reduce the pressure, and then eliminate the fault
When the pressure of the mortar pump does not drop to zero, the air chamber, pressure safety valve and pipeline shall not be disassembled
8
After operation, the grouting pump shall be fully cleaned and the site shall be cleaned
After removing and washing the rubber ball of overload safety valve, its installation position shall be changed to maintain uniform wear
Yuanhua machinery factory provides you with more detailed search tags: double cylinder grouting pump, pneumatic grouting pump, anchor bolt grouting pump, mortar grouting pump, grouting pump
Previous article: price of double liquid grouting pump, HS-6 grouting pump, piston grouting pump and cement grouting pump
Next: single cylinder grouting pump, yellow mud grouting pump, cement grouting pump price, grouting pump manufacturer