Key points for selection of electric control valve:
Key points: 1
It is used for hot water, cold water and low-pressure steam
2
Medium temperature: 1-10 ℃ to 180 ℃
3
0
03 of the leakage Kv value
4
Pressure range: 16bar
5
Diameter: dn15-500
5
The flow coefficient Kv value is 10-360
6
Connection method: screw port and flange
7
Pressure: PN16
8
Valve body material: brass, ductile iron, cast steel
1
The main control parameters for electric control valve are: nominal diameter, design nominal pressure, allowable temperature range of medium, flow coefficient, etc
2
For strict occasions where the flow is required to be in positive proportion to the opening height, a special regulating valve shall be selected
Ball valve and butterfly valve can be selected for rough adjustment
3
The sealing performance of valves is one of the main indexes to evaluate the quality of valves
The sealing performance of the valve mainly includes two aspects, namely, internal leakage and external leakage
Internal leakage refers to the sealing degree of the medium between the valve seat and the closing part
External leakage refers to the leakage of the valve stem packing, the leakage of the middle gasket and the leakage of the valve body caused by casting defects
Leakage is not allowed
4
The ideal flow characteristics of the regulating valve include quick opening, parabolic, linear and equal percentage
The regulating valve with appropriate flow characteristics shall be selected according to the actual working flow characteristics
5
The nominal diameter of the regulating valve shall be determined according to the required valve flow capacity
The nominal diameter of regulating valve shall not be too Da or too small
Over Da, the engineering cost is increased, the valve is in a low percentage range, the adjustment accuracy is reduced, and the control performance becomes worse
If it is too small, the system resistance will increase, and even when the valve is 100% open, the system still cannot meet the set capacity requirements
6
Regulating pressure difference and shut-off pressure difference of regulating valve: for regulating valve, the allowable regulating pressure difference and shut-off pressure difference are important indicators for its type selection
If the actual differential pressure is higher than the allowable regulating differential pressure of the regulating valve, the valve will not be adjusted accurately, which will seriously damage the valve actuator
Contacts
- Company Name
- Zhejiang Baolun fluid intelligent control equipment Co., Ltd
- Name:
- Ms. Wuxiaohua
- Q Q
- 419637671
- Telephone
- 0576-87118088
- Mobile
- 18967694809
Address
- Operational Address
- Qing Gang Zhen Shao wa Cun, Yuhuan City, Taizhou City, Zhejiang Province
Find Similar Products By Category
premiumexporter.com温馨提示
本网页所展示的有关【Selection of two-way and three-way proportional integral electric control valve for Zhejiang Baolun central air conditione】的信息/图片/参数等由的会员【Zhejiang Baolun fluid intelligent control equipment Co., Ltd】提供,由premiumexporter.com会员【Zhejiang Baolun fluid intelligent control equipment Co., Ltd
】自行对信息/图片/参数等的真实性、准确性和合法性负责,本平台(本网站)仅提供展示服务,请谨慎交易,因交易而产生的法律关系及法律纠纷由您自行协商解决,本平台(本网站)对此不承担任何责任。您在本网页可以浏览【Selection of two-way and three-way proportional integral electric control valve for Zhejiang Baolun central air conditione】有关的信息/图片/价格等及提供【Selection of two-way and three-way proportional integral electric control valve for Zhejiang Baolun central air conditione】的商家公司简介、联系方式等信息。
在您的合法权益受到侵害时,请您致电,我们将竭诚为您服务,感谢您对premiumexporter.com的关注与支持!