Lanyu tt3100 thickness gauge
1
Fast measurement speed
2
High precision :
3
Good stability,
4
Function, data, operation, full Chinese display menu
5
Printing function; You can choose to connect to a computer or printer as needed
6
3-year warranty
7
The operation is simple, and there is no need for calibration in normal use
8 various probes can be selected according to needs
Tt3100 thickness gauge is a portable measuring instrument, which can measure the thickness of coating and coating quickly, without damage and accurately
It can be used in both laboratory and project site
The instrument adopts two thickness measurement methods of magnetic and eddy current, which can nondestructive measure the magnetic metal matrix ( such as steel, iron, alloy and hard magnetic steel, etc
) The thickness of non-magnetic covering layer (such as aluminum, chromium, copper, rubber, paint, etc
) and the thickness of non-conductive covering layer (such as enamel, rubber, paint, plastic, etc
) on non-magnetic metal substrate (such as copper, aluminum, zinc, tin, etc
)
The instrument can be widely used in electroplating, anti-corrosion, chemical industry, automobile, shipbuilding, light industry, commodity inspection and other testing fields
Operating ambient temperature: 0-40 ℃ ,
Power supply: 9V , Weight: 300g ,
Overall dimension: 150 * 80 * 30MM
Measuring range: F1, N1, F1 / 90 --- 0 --- 1250um F400、N400----0-400um ; F10: 0---10mm
Measurement error: F1 N1
F1/90-------± ( 2%H+1) Two point calibration accuracy 1%
F10----± (2%H+10) Two point calibration accuracy 1%
F400
N400-----± ( 2%H+0
7) Two point calibration accuracy 1% ,
Note: H - nominal value
Function: , All kinds of probes (F400, F1, F1 / 90 & deg;, F10, N1, N400, etc
) can be used for Measurement ,
Three calibration methods: One point calibration, two-point calibration and basic calibration
Display resolution: 0
1μ M (the measurement range is less than 100um) 1μ m (the measurement range is greater than 100 & mu; m) , Set five statistics to store 500 data ,
There are two working modes: direct mode and group mode ,
There are two measurement methods: continuous measurement and single measurement;
There are two shutdown modes: manual shutdown and automatic shutdown ,
Gauge can be set: the measured values outside the gauge can be automatically prompted, and a batch of measured values can be analyzed by histogram
Deletion function: it can delete large errors and wrong settings
There is music to prompt the operation at any time
With power undervoltage indication function ,
Error prompt function ,
Basic configuration: 1 host , 、 F1 or N1 Probe 1 set of standard calibration piece Matrix, etc