Eds-405a / 408a series are 5-port and 8-port entry-level network managed Ethernet switches designed for industrial applications
Eds-405a / 408a series supports a variety of network management functions, including: Turbo ring, turbo chain, ring coupling, IGMP snooping, IEEE 802
1Q VLAN, port based VLAN, QoS, RMON, bandwidth management, port mirroring function, and alarm triggered by events output through e-mail or relay
The turbo ring function of eds-405a / 408a can be easily configured through the web-based management interface or with the dial switch located on the top panel of eds-405a / 408a switch
Advantages and characteristics
• Command line interface (CLI), which can quickly configure the main network management functions
• Obtain IPv6 ready mark (certified by IPv6 mark Committee)
• DHCP option 82 is used to allocate IP addresses with different policies
• Support Ethernet / IP and Modbus / TCP and PROFINET * industries to
Ethernet protocol
• Support Ethernet / IP EDS (electronic data sheet) documents and customized AOI (attached)
And factorytalk & reg; Visualization panel
• PROFINET GSDML document and SIMATIC effective 7-step device Icon
• Support turbo ring, turbo chain (self healing time & lt; 20 ms @ 250
Switches), RSTP / STP network redundancy
• IGMP snooping and GMRP filtering multicast packets
• Support port based VLAN, IEEE 802
1Q VLAN and GVRP protocols,
Simple network planning
• Support QoS (ieee802
1p and TOS / DiffServ) to increase network stability
• RMON is adopted to effectively improve the network monitoring and prediction ability
• Support SNMPv1 / V2C / V3 network management protocols of different levels
• Support bandwidth management to ensure network stability
• Support port mirroring function for online debugging
*Eds-405a / 408a-pn series only
Hardware specifications and technical reference standards:
IEEE 802
3 for 10baset
IEEE 802
3u is applicable to 100BaseT (x) and 100BaseFX
IEEE 802
3x for flow control
IEEE 802
1d-2004 is applicable to spanning tree protocol
IEEE 802
1w for rapid STP
IEEE 802
1p for class of service
IEEE 802
1Q for VLAN tagging
Protocol: igmpv1 / V2, GMRP, GVRP, SNMPv1 / V2C / V3,
DHCP Server/Client,TFTP,SNTP,SMTP,RARP,RMON,
HTTP,Telnet,Syslog,DHCP Option 66/67/82,BootP,
LLDP,PROFINET*,EtherNet/IP,Modbus/TCP,IPv6,
NTP Server/Client
MIB:MIB-II,Ethernet-Like MIB,P-BRIDGE MIB,Bridge
MIB,RSTP MIB,RMON MIB Group 1,2,3,9
Flow control: IEEE 802
3x flow control, back pressure flow control
*Eds-405a / 408a-pn series only
Switch attribute MAC address table size: 2 K (eds-405a), 8 K (eds-408a)
Packet buffer size: 1 Mbit
Interface optical fiber interface: 100BaseFX port (SC / St interface)
RJ45 port: 10 / 100BaseT (x) automatic negotiation speed, full / half duplex mode,
And automatic MDI / mdi-x connection
Control port: RS-232 (RJ45 interface)
Dip switch: Turbo ring, master, coupler, reserve
LED indicator: pwr1, pwr2, fault, mstr / head,
CPLR/TAIL,10/100M
Alarm output: one relay output, current load capacity 1 a @ 24 VDC
Optical fiber
Power demand input voltage: 24 VDC (12 ~ 45 VDC), dual redundant input
Input current:
EDS-405A,EDS-405A-EIP,EDS-405A-PN:0
24 A @ 24 V
EDS-405A-MM/SS:0
32 A @ 24 V
EDS-408A,EDS-408A-EIP,EDS-408A-PN:0
26 A @ 24 V
EDS-408A-MM/SS:0
35 A @ 24 V
EDS-408A-3M/3S/2M1S/1M2S:0
32 A @ 24 V
Overload protection: provided
Interface: 1 pluggable 6-pin terminal block
Reverse connection protection: provided
Mechanical characteristics shell: metal, IP30 protection grade
Dimensions: 53
6 x 135 x 105 mm (2
11 x 5
31 x 4
13 in)
Weight:
EDS-405A,EDS-405A-MM,EDS-405A-SS,EDS-405A-PN,
EDS-405A-EIP: 650 g
EDS-408A,EDS-408A-MM,EDS-408A-SS,EDS-408A-PN,
EDS-408A-EIP: 650 g
EDS-408A-3M/3S/2M1S/1M2S: 890 g
Installation method: guide rail and wall hanging (optional Kit)
Working environment working temperature:
Standard model: 0 ~ 60 & deg; C(32 ~ 140 °F)
Wide temperature model: - 40 ~ 75 ° C(-40 ~ 167 °F)
Storage temperature: - 40 ~ 85 ° C(-40 ~ 185 °F)
Relative humidity: 5 ~ 95% (no condensation)
Safety certification: UL 508, UL 60950-1 *, CSA C22 2 No
60950-1,
EN 60950-1**
Hazardous Location:UL/cUL Class 1 Division 2
Groups A/B/C/D*,
ATEX Zone 2 Ex nA nC IIC T4 Gc***,
ATEX Zone 2 Ex nA nC op is IIC T4 Gc****
EMI:FCC Part 15 Subpart B Class A,EN 55022 Class A
EMS:
EN 61000-4-2 (ESD) Level 3,EN 61000-4-3 (RS) Level 3,
EN 61000-4-4 (EFT) Level 3,EN 61000-4-5 (Surge) Level 3,
EN 61000-4-6 (CS) Level 3,EN 61000-4-8
Marine:EDS-405A/408 A,EDS-405A/408A 2 Fiber
series:DNV,GLEDS-408A 3 Fiber series:DNV,GL,LR,
ABS,NK
Traffic Control:NEMA TS2
Rail Traffic:EN 50121-4**
Shock:IEC 60068-2-27
Freefall:IEC 60068-2-32
Vibration:IEC 60068-2-6
*Eds-405a / 408a, only eds-405a / 408a two fiber series
**Eds-408a only
***Eds-405a, only eds-405a 2 fiber series
****Eds-408a, only eds-408a 2 fiber series
Note: please visit moxa website to get the latest certification information
MTBF (mean time between failures): eds-405a series: 392000 hours
Eds-408a series: 1102845 hours
Database: Telcordia (Bellcore), GB
Warranty period: 5 years
Optional models |
Td> | Product No | Description |
Td> | Eds-405a / 408a-pn-t | Style = "Arial: PX" font style = "0x; PX style =" bottom-208, PX: PX> font style = "Arial: PX; PX style =" bottom-208; "/ PX: border style =" Arial: PX; PX "font style =" bottom-208; "> Td> | Eds-405a / 408a-eip-t | Wide temperature model (- 40 ~ 75 & deg; c), 5 / 8 10 / 100BaseT (x) |
Td> | Eds-405a / 408a-pn | Standard model (0 ~ 60 & deg; c), 5 / 8 10 / 100BaseT (x) |
Td> | Eds-405a / 408a-eip | Standard model (0 ~ 60 & deg; c), 5 / 8 10 / 100BaseT (x) |
Td> | Eds-408a-1m2s-sc-t | Wide temperature model (- 40 ~ 75 & deg; c), 5 10 / 100BaseT (x), 1 multimode, SC connector, 2 single-mode, SC connector |
Td> | Eds-408a-1m2s-sc | Standard model (0 ~ 60 & deg; c), 5 10 / 100b
Contacts
- Company Name
- Hangzhou Yongning Technology Co., Ltd
- Name:
- Mr. Zhong Zhong
- Telephone
- 86-0571-88476509
- Mobile
- 13600533667
Address
- Operational Address
- Room 407, building 4, Wuzhou international business center, Xihu District, Hangzhou
Find Similar Products By Category
premiumexporter.com温馨提示
本网页所展示的有关【Model 4058a / 405 industrial network management switch and entry-level eda-8a】的信息/图片/参数等由的会员【Hangzhou Yongning Technology Co., Ltd】提供,由premiumexporter.com会员【Hangzhou Yongning Technology Co., Ltd
】自行对信息/图片/参数等的真实性、准确性和合法性负责,本平台(本网站)仅提供展示服务,请谨慎交易,因交易而产生的法律关系及法律纠纷由您自行协商解决,本平台(本网站)对此不承担任何责任。您在本网页可以浏览【Model 4058a / 405 industrial network management switch and entry-level eda-8a】有关的信息/图片/价格等及提供【Model 4058a / 405 industrial network management switch and entry-level eda-8a】的商家公司简介、联系方式等信息。
在您的合法权益受到侵害时,请您致电,我们将竭诚为您服务,感谢您对premiumexporter.com的关注与支持!
|