  Overview 1
1 system purpose and characteristics
KJ616 (A) The dynamic monitoring system of coal mine roof is a computer online measurement system for the working resistance of fully mechanized mining support in coal mine
The system integrates computer detection technology, data communication technology and sensor technology to monitor the working resistance and other ground pressure parameters of fully mechanized mining support in real time, so as to evaluate the working state of support and the adaptability between support and geological conditions, and study the ground pressure behavior of mining face It provides a basis for roof management of working face

2
System model and its representative significance
3
Explosion proof type
It consists of mine intrinsic safety type, mine flameproof and intrinsic safety type coal mine roof dynamic monitoring system
(see kj616 (a) list of main parts (components) and important raw materials of coal mine roof dynamic monitoring system for details)

4
Use environment
4
1 the equipment used in the dispatching room of the machine room in the system works normally under the following conditions:
a) Ambient temperature: 15 ℃ ~ 30 ℃;
b) Relative humidity: 40% ~ 70%;
c) Temperature change rate: less than 10 ℃ / h without condensation;
d) Atmospheric pressure: 80kPa ~ 106kpa;
e) Dust, lighting, noise, electromagnetic field interference and grounding conditions specified in GB / T 2887

4
2 the equipment used in coal mine underground in the system works normally under the following conditions:
a)  Ambient temperature: 0 ℃ ~ 40 ℃;
b)  Not more than 95% (+ 25 ℃);
c)  Atmospheric pressure: 80kPa ~ 106kpa;
d)  Corrosive gas with explosive gas mixture but no significant vibration and impact and no balanced insulation

5
Power supply
5
1 AC power supply of ground equipment:
a) Rated voltage: ac127v / 220V / 660V, allowable deviation - 10% ~ + 10%;
b) Harmonic: no more than 5%;
c) Frequency: 50Hz, allowable deviation & plusmn; 5%。
5
2 underground AC power supply:
a) Rated voltage: ac127v / 660V, allowable deviation - 25% ~ + 10%;
b) Harmonic: no more than 10%;
c) Frequency: 50Hz, allowable deviation & plusmn; 5%。
6
System design requirements
6
1 system composition
The system consists of monitoring main and standby computers, printers, uninterruptible power supply, power lightning arrester, RS485 / USB converter Kj616 (a) - J mine intrinsically safe data transmission interface (hereinafter referred to as the interface), kj616 (a) - F1 mine intrinsically safe transmission master station (hereinafter referred to as the master station), kj616 (a) - F2 mine intrinsically safe monitoring substation (hereinafter referred to as the substation), sensors, kdw28-18 (a) mine flameproof and intrinsically safe uninterruptible power supply and cables

See Appendix A for system composition block diagram

6
2 hardware
See the list of main parts (components) and important raw materials for each component equipment in the system

6
3 software configuration
  a) Operating system: WindowsXP, windows7

b) Database: SQL Server 2000

d) Monitoring software: kj616 (a) coal mine roof dynamic monitoring software

7
Basic functions
7
1 data acquisition function
The system shall have the functions of mine pressure, stress and roof displacement analog acquisition, display and alarm

7
2 storage and query functions
7
2
1
The system has storage and query functions, including:
a) Real time monitoring value of analog quantity at important measuring points;
b) Statistical value of analog quantity;
c) Alarm and alarm release time and status;
d) Equipment failure / recovery of normal working time and state, etc

7
3 display function
7
3
1
The system has the function of list display
Analog quantity and related display contents include: location, name, unit, alarm threshold, monitoring value, sensor working state, alarm and alarm release state and time, etc

7
3
4
The system has the function of displaying analog real-time curve and historical curve
The maximum, average, minimum and other curves are displayed in different colors on the same coordinate
On one screen, not less than 3 analog quantities can be displayed at the same time, and a time scale is set to display the analog value of the corresponding time scale

7
3
5
The system has the function of analog animation display
The display contents include: process flow simulation diagram, corresponding analog value, etc
It has the methods of general drawing and local enlargement

7
3
6
The system has the display function of system equipment layout
The display contents include: equipment name, relative position and operation status of sensor, master station and substation
If the system is too large to be accommodated on one screen, the general drawing can be enlarged locally

7
4 printing function
The system has call printing functions such as report, curve, simulation diagram and initialization parameters

7
5 man machine dialogue function
The system has man-machine dialogue function to facilitate system generation, parameter modification, function call, control command input, etc

7
6 self diagnosis function
The system has self diagnosis function
When the sensor, master station and substation in the system fail, alarm and record the fault time and fault equipment for query and printing

7
7 dual computer switching function
The system has dual computer switching function
The system host shall have dual backup and manual switching function
When the working host fails, the backup host is put into operation

7
8 data backup function
The system has data backup function

7
9 standby power supply
The system has standby power supply
In case of power failure, the system shall be able to continuously monitor the main monitoring quantities of mine pressure, stress and roof displacement

7
10 lightning protection function
Dxh06-f power lightning arrester is connected to the AC power supply incoming line of the central station machine room for lightning protection

7
11 other functions
a) The system has network communication function;
b) The system has software self-monitoring function;
c) The system has software fault tolerance function;
d) The system has the function of real-time multitasking, which can transmit, process, store and display information in real time, and control it in real time according to the requirements
It can run periodically without interruption

8
Main technical indicators
8
1 analog input transmission processing error
Analog input transmission processing error shall not be greater than 1
0%

8
2 maximum patrol inspection cycle
The maximum patrol inspection cycle of the system shall not be greater than 30s

8
3 picture response time
85% of the response time of calling out the whole picture shall not be greater than 2S, and that of other pictures shall not be greater than 5S

8
4 bit error rate
The bit error rate shall not be greater than 10-8

8
5 maximum transmission distance
a) The maximum transmission distance from computer to RS485 / USB converter and from converter to interface is 2m

b) The maximum transmission distance from the interface to the master station is 10km (mgtsv (2 ~ 96) B communication optical cable is used);
c) The maximum transmission distance from the main station to the substation is 2km (mhyv 1 & times; 4 (7 / 0
37mm) communication cable is used, and the cross-sectional area of single core wire is 0
75mm2);
d) The maximum wireless transmission distance from the substation to the sensor is 100m (unobstructed)

8
6 maximum monitoring capacity
The system can access up to 8 substations, and each substation can access up to 64 supporting sensors

8
7 dual machine switching time
The time from the failure of the working host to the normal operation of the standby host shall not be more than 5min

8
8 working time of standby power supply
After power failure of the power grid, the standby power supply shall ensure that the continuous monitoring time of the system shall not be less than 2H

8
9 storage time
The real-time monitoring value of analog quantity at important monitoring points shall be saved for more than 7 days
The records of analog statistical value, alarm / alarm release time and status, equipment failure / recovery time and status shall be kept for more than 1 year
In case of system failure, the time length of losing the above information shall not be greater than 5min

8
10 statistical time
The statistical value of analog quantity shall be the statistical value of 5min

8
11 maximum combined load and intrinsically safe power supply distance
Kdw28-18 (a) mine flameproof and intrinsically safe uninterruptible power supply, one circuit of 18V (IB grade, open circuit): it can supply power to one set of kj616 (a) - J mine intrinsically safe data transmission interface or kj616 (a) - F1 mine intrinsically safe transmission master station or kj616 (a) - F2 mine intrinsically safe monitoring substation
The maximum power supply distance is 5m (mhyv 1 & times; 4 (7 / 0
37mm) communication cable is used, and the cross-sectional area of single core wire is 0
75mm2)

9
Transmission performance
9
1 transmission between computer and RS485 / USB converter
1)  Transmission mode: USB;
2)  Number of interfaces: 2 computers and 1 RS485 / USB converter

9
2 transmission between RS485 / USB converter and interface
1)  Transmission mode: master-slave, half duplex, RS485;
2)  Transmission rate: 115200bps;
3)  Number of interfaces: 1 converter and 2 interfaces

9
3 transmission between interface and master station
1) Transmission mode: Ethernet optical signal (wavelength 1310nm);
2) Transmission rate: 100Mbps;
3) Optical emission power: (- 20 ~ 0) DBM;
4) Number of interfaces: 1 interface and 1 master station;
9
4 transmission between master station and substation
1) Transmission mode: master-slave, half duplex, RS485;
2) Transmission rate: 4800bps;
3) Number of interfaces: 1 master station and 1 sub station

9
5 transmission between substation and supporting sensors
1) Transmission mode: GFSK wireless transmission;
2) Center operating frequency: 450MHz & plusmn; 2MHz;
3) Transmission power: - 20dbm ~ 20dbm

Contacts
Company Name
Shandong HengAn Electronic Technology Co., Ltd
Name:
Mr. Zhao you LIU manage
Q Q
2268316428
Telephone
0538-6306499
Mobile
18864833578
Address
Operational Address
Longhe commercial building, Wuma street, Taishan District, Tai'an City
premiumexporter.com温馨提示

本网页所展示的有关【Hengan ground pressure monitoring system kj616 (a)】的信息/图片/参数等由的会员【Shandong HengAn Electronic Technology Co., Ltd】提供,由premiumexporter.com会员【Shandong HengAn Electronic Technology Co., Ltd 】自行对信息/图片/参数等的真实性、准确性和合法性负责,本平台(本网站)仅提供展示服务,请谨慎交易,因交易而产生的法律关系及法律纠纷由您自行协商解决,本平台(本网站)对此不承担任何责任。您在本网页可以浏览【Hengan ground pressure monitoring system kj616 (a)】有关的信息/图片/价格等及提供【Hengan ground pressure monitoring system kj616 (a)】的商家公司简介、联系方式等信息。

在您的合法权益受到侵害时,请您致电,我们将竭诚为您服务,感谢您对premiumexporter.com的关注与支持!