WDM dissolved oxygen online monitor, imported sewage dissolved oxygen analyzer
Principle: dissolved oxygen by fluorescence method
Interference factor: it has strong anti-interference ability and is basically not easy to be affected by other interference substances
Condition limitation: it will not consume dissolved oxygen in water, and there is no requirement for small flow rate of measuring medium
Stability and reliability: the fluorescent cap can still maintain its accuracy in case of scraping or partial pollution, and it is easy to clean
Maintenance amount: the maintenance amount is low
There is no need to calibrate and replace the electrolyte and film head, but only replace the fluorescent cap
Dissolved oxygen analyzer & mdash& mdash; Main technical indicators
Measurement range: 0-20 mg / L, 0-20 ppm;
Measurement accuracy: measured value & plusmn; 3%;
Calibration: automatic air calibration, sample calibration
Sensor material: SUS316L + PVC (normal version)
Titanium alloy + PVC (seawater version)
Communication protocol: MODBUS RS485
Protection grade: IP68 / nema6p
Cable length: Standard 10m cable, which can be extended to 100m
Size: diameter 49
5mm * length 251
3mm
Weight: 1
4kg
It is widely used in dissolved oxygen monitoring in sewage plants, waterworks, water stations, surface water, aquaculture, industry and other fields
Do on-line monitoring of various process processes such as regulating tank, biochemical tank and effluent of sewage treatment plant;
Dissolved oxygen online sensor
The dissolved oxygen sensor measures dissolved oxygen by fluorescence method
The blue light emitted irradiates on the fluorescent layer, and the fluorescent material is excited to emit red light, and the oxygen concentration is inversely proportional to the time when the fluorescent material returns to the ground state
Using this method to measure dissolved oxygen, there is no oxygen consumption during measurement, the data is stable, the performance is reliable, there is no interference, and the installation and correction are simple
Breakthrough fluorescence technology with strong anti-interference ability
Without membrane and electrolyte, maintenance is basically unnecessary
Measurement does not consume oxygen and there is no flow rate / agitation requirement
Automatic air calibration
Place the sensor in the air and allow the instrument data to stabilize before starting calibration, while avoiding direct sunlight
Ensure that the settings of the sensor are correct
Contacts
- Company Name
- Jiangyuan (Chongqing) Technology Group Co., Ltd
- Name:
- Mr. Tang Song
- Q Q
- 2215257886
- Telephone
- 023-68271555
- Mobile
- 15998986518
Address
- Operational Address
- Building 19, No. 399, BOE Avenue, Liangjiang New District, Chongqing
Find Similar Products By Category
premiumexporter.com温馨提示
本网页所展示的有关【Dissolved oxygen analysis of imported sewage】的信息/图片/参数等由的会员【Jiangyuan (Chongqing) Technology Group Co., Ltd】提供,由premiumexporter.com会员【Jiangyuan (Chongqing) Technology Group Co., Ltd
】自行对信息/图片/参数等的真实性、准确性和合法性负责,本平台(本网站)仅提供展示服务,请谨慎交易,因交易而产生的法律关系及法律纠纷由您自行协商解决,本平台(本网站)对此不承担任何责任。您在本网页可以浏览【Dissolved oxygen analysis of imported sewage】有关的信息/图片/价格等及提供【Dissolved oxygen analysis of imported sewage】的商家公司简介、联系方式等信息。
在您的合法权益受到侵害时,请您致电,我们将竭诚为您服务,感谢您对premiumexporter.com的关注与支持!