R& S® RTM digital oscilloscope has excellent test performance and rich measurement functions
It is a good choice for product R & D and product maintenance
The oscilloscope has compact structure, simple operation and bright and clear display effect
It is very suitable for daily testing and measurement R&S® RTM oscilloscope can provide 500 MHz bandwidth, 5g sample / s sampling rate and 8m sample storage depth
Therefore, signals, including signal details, can be displayed accurately and have high time resolution, even for long sequence signals
In addition, R & S & reg; RTM oscilloscope also has other excellent characteristics, such as extremely low inherent noise and excellent channel isolation, which makes the measurement results extremely accurate and reliable
In addition to daily measurement and analysis, the oscilloscope also has several special highlights, which can help users quickly get the required results in the process of debugging and signal analysis
For example, just press one button, & ldquo; QuickMeas ” The function can graphically display the main measured values of the currently active signal and continuously update these values
For cursor measurement, these oscilloscopes can also provide more functions than traditional vertical and horizontal cursors
For example, they have peak voltage measurement function, and can also provide pulse automatic counting function, etc
Although R & S & reg RTM oscilloscope has a variety of rich measurement functions, but its operation and use are very simple and intuitive
This product adopts 8
4 & ldquo; The color XGA TFT display has bright color, clear imaging and high resolution
Even small signal details can be seen at a glance
Despite having a relatively large display screen, these instruments are small in size and light in weight
All this makes them attractive general-purpose oscilloscopes, which are suitable for portable and multifunctional applications
Quickly and efficiently troubleshoot signal faults
With rich trigger options, it can continuously * key signal events
It can display accidental events with high brightness to make debugging easier and optimize the main interface: x
y (one z) mode signal acquisition mode supports a variety of options
Smooth & rdquo; Mode
It can smooth aperiodic signals
High time resolution even in the face of long signal sequence
The more details the oscilloscope can display, the more likely the user may find signal faults or important events
One of the preconditions is that the oscilloscope must have high time resolution, that is, high sampling rate
In addition, many applications require longer acquisition cycles, for example, for transient analysis
This is R & S & reg Success of RTM oscilloscope: with a sampling rate of up to 5g sample / s and a memory depth of up to 8m sample, the oscilloscope balances these two requirements very well
In addition, regardless of other settings of the instrument, its memory depth can always be used
Low noise front end, excellent measurement accuracy
The signal accuracy displayed on the display screen largely depends on the inherent noise of the oscilloscope
To this end, R & S & reg RTM oscilloscope uses low-noise front-end and low-noise analog-to-digital converter
Therefore, they can achieve accurate measurement even under the condition of small vertical resolution
Full measurement bandwidth, even if the input sensitivity is 1 mV / Div
R&S® The input sensitivity of RTM oscilloscope is up to 1 mV / div, with very high vertical resolution
In order to achieve such high input sensitivity, some oscilloscopes must adopt software based scaling technology or limit the bandwidth
In contrast, even with a resolution of 1 mV / div, R & S & reg RTM oscilloscope can also display the real test point of the signal
Moreover, the full measurement bandwidth can be used
Therefore, they have outstanding high measurement accuracy, even measuring very small signal details
Good isolation is achieved between channels without crosstalk
In some oscilloscopes, when other channels are used, the measurement accuracy of the current channel will deteriorate
R&S® RTM oscilloscope has very good channel isolation
When it does not exceed 500 MHz, its isolation & gt; 50 dB。 This feature ensures that the possible interference between signals of different channels is reduced to less
Trigger and decoding of serial protocol
R&S® RTM oscilloscope provides multi-functional tools, which can provide protocol related triggering and decoding for widely used serial interfaces, such as I2C, SPI, UART / RS-232, etc
Rich trigger options help to get all important events
For example, for I2C message, the oscilloscope can trigger a specific address containing specific data content
After successful decoding, the protocol data can be displayed in the form of ASCII, binary, hexadecimal or decimal data
Different sections of the message (address, data, start bit, etc
) are highlighted in color to make it easier to analyze
Another very useful feature is that with the increase of the scaling factor, the display of decoded information will become more and more detailed and specific