Welcome !

Qingdao Hesheng Zhiyuan Automation System Co., Ltd

企业会员1YEAR

Qingdao Hesheng Zhiyuan Automation System Co., Ltd

Country:Nationwide,China

Business:Smart heating network system, IC card prepayment system, GPRS Remote meter reading system, special equipment vortex flowmeter, vortex flowmeter with supervis…

Dandong IC card steam flowmeter and mixed gas flowmeter are cheap

PriceCN ¥4862.00

Brand
Qingdao Zhiyuan Instrument Co., Ltd
Quantity
1272 ̨
Min. Order
1 ̨
Country
ShandongQingdao,China
Recommended For You
品牌:
Qingdao Zhiyuan Instrument Co., Ltd
  Qingdao Hesheng Zhiyuan Automation System Co
, Ltd
specializes in the production of vortex flowmeter, which is mainly used for the flow measurement of medium fluid in industrial pipeline, such as gas, liquid, steam and other media
IC card steam flowmeter is characterized by small pressure loss, large range and high precision
It is almost unaffected by fluid density, pressure, temperature, viscosity and other parameters when measuring volumetric flow under working conditions
There are no movable mechanical parts, so it has high reliability and small maintenance
The instrument parameters can be stable for a long time
The clamped vortex flowmeter adopts piezoelectric stress sensor, which has high reliability and can work in the working temperature range of - 20 ℃ ~ + 250 ℃
With analog standard signal and digital pulse signal output, it is easy to be used together with digital systems such as computers
It is a kind of comparative and flow measuring instrument
Dandong IC card steam flowmeter and mixed gas flowmeter are cheap
The standards and regulations were promulgated in 1989, which played a role in standardizing the development, production and application of vortex flowmeter in China
According to statistics in 1992, there are more than 30 enterprises developing and producing vortex flowmeter in China
Matters needing attention in the installation of vortex flowmeter 1 The flowmeter must be installed as required to avoid damage to the instrument due to improper installation and affecting the measurement accuracy
2 The flowmeter shall not be installed on the long overhead pipeline as far as possible
The sagging of the pipeline is easy to cause the seal leakage between the flowmeter and the flange If it is necessary to install, pipe support points shall be set at 2D upstream and downstream of the flowmeter, the double generator and double detection element stress vortex flowmeter shall be successfully developed, and the dry calibration technical indicators shall be provided to the customer in the installation and use manual; In the measurement system, the vortex flow sensor is installed on the vertical pipe, which sends the pulse signal corresponding to the high-pressure air flow to the intelligent flow integrator
Precautions for IC card steam flowmeter installation of Qingdao Hesheng Zhiyuan Automation System Co
, Ltd
:
When the special flange of vibration resistant vortex flowmeter is welded with the straight pipe section, the sensor cannot be used for welding
During installation, the flow direction mark of the sensor shall be consistent with the flow direction of the fluid in the pipeline
Before installing the sensor, the sealing ring must be placed in the flange groove
The position of pressure and temperature measuring points, the pressure taking point is 3 ~ 5dn downstream of the sensor, and the temperature measuring point is 5 ~ 8dn downstream
When measuring high-temperature medium with distilled water vortex street flowmeter, do not wrap around the sensor connecting rod with thermal insulation material
The direction of the * cable connecting the sensor shall be far away from the occasion of strong electromagnetic field as far as possible
It is not allowed to be laid together with the high-voltage cable, * the cable shall be shortened as far as possible and shall not be coiled to reduce the distributed inductance
The large length shall not exceed 100m
Before installing the sensor of Qingdao flowmeter, the pipeline must be cleaned
Flush out the impurities in the pipe to avoid blocking the sensor after flow
The pipeline for measuring liquid must be filled with the measured liquid to prevent the formation of bubbles
Dandong IC card steam flowmeter and mixed gas flowmeter have low price
They can display various information such as instantaneous flow, instantaneous heat, cumulative flow, cumulative heat, vortex frequency, medium pressure and temperature, density, time and date
They also have rich functions such as small flow automatic compensation, power failure flow compensation and automatic meter reading
When installing and measuring gas flow on horizontal pipelines, If the measured gas contains a small amount of liquid, the sensor shall be installed at a higher place of the pipeline and processed with a CNC lathe to ensure the accuracy of coaxiality and finish, and cooperate with special process treatment, so as to overcome the common problem of the influence of the inherent self oscillation frequency of vortex flowmeter on the signal
This is the unique technical advantage of keou company in the production of vortex flowmeter
The research and development of mass vortex flowmeter has been carried out at home and abroad
Vortex flowmeter is developing from indirect mass flowmeter to direct mass flowmeter, and the signal processing technology is developing in the direction of digitization
From the application of conventional active filter to the application of * filter, adaptive filter and digital spectrum analysis, the accuracy, anti-interference ability and measurement range of vortex flowmeter are improved
Requirements for straight pipe section of IC card steam flowmeter installation:
1
The anti vibration vortex flowmeter has certain requirements for the upstream and downstream straight pipe sections on the installation point, otherwise the measurement accuracy will be affected
2
At the upstream of the installation point of Jining flowmeter, there shall be an equal diameter straight pipe section of no less than 15d (D is the pipe diameter) at the upstream of the flowmeter and no less than 5D at the downstream
3
The upstream of the installation point of digital display vortex street flowmeter has a gradually expanding pipe, the upstream should have an equal diameter straight pipe section of no less than 18D (D is the pipe diameter), and the downstream should have an equal diameter straight pipe section of no less than 5D
4
There is 90 DEG upstream of the installation point of Weihai flowmeter; For elbow or down joint, there shall be equal diameter straight pipe section of no less than 20d at the upstream and no less than 5D at the downstream of the flowmeter
5
There is 90 DEG on the same plane upstream of the installation point for supervision and inspection of the flowmeter shell; Elbow, the upstream of the flowmeter shall have an equal diameter section of no less than 25d, and the downstream shall have an equal diameter straight pipe section of no less than 5D

Dandong IC card steam flowmeter and mixed gas flowmeter are cheap
According to the needs of measurement, when the pressure and temperature need to be measured near the sensor, the pressure measuring point should be 3-5d downstream of the sensor, and the temperature measuring point should be 6-8d downstream of the sensor
The flow transmitter is 4-20mA analog signal output with strong resistance
It can be directly connected to PLC or DCS to reduce the correction Fen risk of both parties
Development The production unit should also concentrate on research to solve the weak links of vortex flowmeter products and improve product performance and manufacturing quality
The publicity of products should be more objective
The * cable should be used, and the * layer should be reliably connected to the grounding screw of the amplifier or grounded in the control room
When there is oil, solvent or other corrosive gas in the high-temperature or low-temperature environment or on-site air, the * cable suitable for this special occasion shall be used
Qingdao Zhiyuan instrument Dandong IC card steam flowmeter and mixed gas flowmeter are cheap
Ordering instructions:
I When ordering a flow meter, the user shall correctly provide specific parameters such as nominal diameter, nominal pressure, working pressure, working temperature, flow range, whether explosion-proof requirements and type are required

II The ordering and type selection shall be filled in detail according to the requirements of the product model marking table of IC card steam flowmeter

  1
The clamp on vortex flowmeter is made of stainless steel, intrinsically safe and explosion-proof, two-wire system, 4-20mA output, nominal pressure of 1
6Mpa, metering medium is general gas, and the accuracy is grade 1
5

  2
The material of steam meter body is 304, field indication, flameproof, two-wire system, 4-20mA output, and nominal pressure is 1
6Mpa

  3
The measuring medium is saturated steam with accuracy of 1
5
Description: clip on vortex flowmeter, body material 304 stainless steel, nominal diameter of 100mm, field display, non explosion-proof, 24V power supply, nominal pressure of 4
0Mpa, measuring medium liquid, accuracy grade of 1
0

  4
Special requirements shall be supplied as agreed by both parties
Steam anti-seismic vortex flowmeter
Qingdao Hesheng Zhiyuan Automation System Co
, Ltd
189 Huixin 5483 same No
1481
Q:3438-5007-67
Contacts
Company Name
Qingdao Hesheng Zhiyuan Automation System Co., Ltd
Name:
Mr. Manager Liu manage
Telephone
18954831481
Mobile
18954831481
Address
Operational Address
No. 819, Huaguan Road, hi tech Zone 18954831481
premiumexporter.com温馨提示

本网页所展示的有关【Dandong IC card steam flowmeter and mixed gas flowmeter are cheap】的信息/图片/参数等由的会员【Qingdao Hesheng Zhiyuan Automation System Co., Ltd】提供,由premiumexporter.com会员【Qingdao Hesheng Zhiyuan Automation System Co., Ltd 】自行对信息/图片/参数等的真实性、准确性和合法性负责,本平台(本网站)仅提供展示服务,请谨慎交易,因交易而产生的法律关系及法律纠纷由您自行协商解决,本平台(本网站)对此不承担任何责任。您在本网页可以浏览【Dandong IC card steam flowmeter and mixed gas flowmeter are cheap】有关的信息/图片/价格等及提供【Dandong IC card steam flowmeter and mixed gas flowmeter are cheap】的商家公司简介、联系方式等信息。

在您的合法权益受到侵害时,请您致电,我们将竭诚为您服务,感谢您对premiumexporter.com的关注与支持!