Water soluble antirust sealer
Warm tips: before each use, shake evenly before pouring out the cylinder; Before operating the working liquid that has not been used for a long time, it shall be stirred evenly before operation
If conditions permit, after opening the tank, the tank liquid can be stirred continuously by the circulating pump in the process of processing the workpiece, or the air pump can be put into the bottom of the tank to achieve the effect of bubbling and circulating mixing
After the workpiece is processed and used, if the effect test is required, it shall be placed for 12 hours or more before the test
Introduction: d106-5 water soluble antirust sealer is a brown liquid, which is not easy to burn after being diluted with water
It can form a dense protective film on the surface of metal (the effect of workpiece after electroplating is better)
It has strong antirust, anti oxidation and anti discoloration effects, easy to use, easy to operate and simple equipment
It is suitable for metal stamping iron parts, Anti rust and anti-oxidation treatment of various standard parts after plating (such as 201 stainless iron, 304 stainless steel, nickel, pure copper, brass plating, red copper plating, chemical nickel, blackening, black nickel, tin, chromium, etc
) shall be applied to electroplating, continuous electroplating and chemical plating
The antirust ability and salt spray resistance of the treated workpiece can greatly enhance the surface gloss, will not stick together, and will not affect the conductivity and welding
For steel without electroplating, stainless steel metal also has good anti rust ability
Operation flow: electroplating workpiece → Two washes → Passivation & rarr; Two washes → Soak in water-soluble antirust sealer & rarr; Centrifuge drying → Drying (drying directly without washing water until the white liquid just disappears, and too long drying time will affect the appearance and salt spray resistance) → packing
Operation process:
Concentration: 2-20% (i
e
2-20 liters of water-soluble antirust sealant in 100 liters of working fluid, 80-98 liters of pure water or clean tap water, and the standard value is 5% - 10%)
Working fluid temperature: please dilute with normal temperature water
In winter or when the temperature is low, please dilute with 35-50 ℃ hot water
Time: 30 seconds - 5 minutes (if time permits, it is recommended to soak for more than 3 minutes)
Drying temperature: 50-80 ℃ (the soaked workpiece can be dried after dehydration by centrifuge without washing)
Concentration usage parameters:
concentration
| workpiece surface state after treatment
| salt fog resistance (neutral)
|
2-5% (it is recommended to dilute with pure water)
| almost no oil feeling
| no rust in 18-28 hours
|
6-10% (it is recommended to dilute with pure water)
| slight oil feeling
| no rust in 24-50 hours
|
20% (it is recommended to dilute with pure water)
| moderate oil feeling
| no rust in 50-124 5 hours
|
note: 1 Before each use, be sure to shake the stock solution of water-soluble antirust sealant evenly before pouring it out of the cylinder The temperature of diluted water is 30-40 ℃, 2 The working fluid that has not been used for a long time shall be stirred evenly before operation 3 The above data are only for reference (due to different plating layers, plating types and workpiece materials) 4 Working fluid maintenance is calculated and added according to the brought out volume 5 It is recommended to replace the working fluid after one week of use
6 If there are spots on the surface of the workpiece after treatment, reduce the workpiece and drying temperature to 40-50 ℃, and operate the spotted workpiece again without re electroplating 7 If you have any problems during operation, please call to solve them
|
note:
1
Due to different raw materials and temperatures, the stock solution may be layered during storage
This is a normal phenomenon and will not affect the antirust effect
Sometimes it dissolves faster and sometimes slower
It is a normal phenomenon
Please rest assured to use it
2
If the anti rust and anti salt fog ability is poor, please extend the soaking time or increase the concentration
If the oil feeling is too heavy, please reduce the concentration
3
If the hanger is directly put into this product for treatment, please clean it and then put it into the plating bath, so as not to bring Yao water into the plating bath and affect the plating bath
4
If the test results fail to meet your requirements, please tell us the reason so as to provide a more suitable model
Packaging: 200ml / bottle, 500ml / bottle, 1L / bottle, 5L / barrel, 25L / barrel
Shelf life: 12 months
Storage: Please store in a cool and ventilated place, away from high temperature, open fire and inflammables
Statement: the contents and suggestions of this manual are based on the experimental data of our company; Due to the differences in operation and equipment among users, the company does not make any warranty for the results of the use of relevant products of the company, nor is it responsible for the damage caused by adverse results
All materials in this manual shall not be used as a basis for copyright infringement