Characteristics and identification methods of low smoke halogen-free flame retardant wires of Zhengzhou first cable Co
, Ltd
What are the characteristics and identification methods of low smoke halogen-free flame retardant wires? We don't know anything about low smoke halogen-free flame retardant wires
Many people only know about wires, but we know very little about wires for different purposes
Therefore, if we want to know about low smoke halogen-free flame retardant wires, we must first understand the characteristics and identification methods of low smoke halogen-free flame retardant wires? The specific knowledge answers are as follows: What are the characteristics of low smoke halogen-free flame retardant wires The purpose of each kind of wire is different because it has the characteristics that other wires do not have
Therefore, before purchasing low smoke halogen-free flame retardant wires, let's first understand the characteristics of low smoke halogen-free flame retardant wires 1
Characteristics of low smoke halogen-free flame retardant wire -- the tensile strength is greater than that of ordinary PVC wire: the tensile strength of ordinary PVC wire is greater than 1
05kgf/mm2, while the tensile strength of low smoke halogen-free wire is greater than 1
2kgf/mm2; 2
Characteristics of low smoke halogen-free flame retardant wire - good weather resistance (- 30 ℃ ~ 105 ℃); Good softness (hardness 80-90); 3
Characteristics of low smoke halogen-free flame retardant wire - non mobility (because this product formula does not need to add plasticizer, it will not have mobility); No toxic black smoke will be produced during combustion (a small amount of white smoke will be produced); It has high volume resistivity: PVC wire is generally 1012 ~ 1015 & omega/ Cm3, low smoke halogen-free wire greater than 1016 & omega/ cm3; (7) It has good high-voltage resistance characteristics: PVC wires are generally resistant to more than 10kV, while low smoke halogen-free wires are up to more than 15kV; (8) It has good elasticity and viscosity What is the identification method of low smoke halogen-free flame retardant wire 1
Product name identification method for identification method of low smoke halogen-free flame retardant wire
Wire - low smoke halogen-free flame retardant polyethylene insulated wire and cable; Cable - low smoke halogen-free flame retardant polyethylene insulated low smoke halogen-free flame retardant polyethylene sheathed power cable
Generally, the name of the imitation products will be a little different, such as polyethylene insulated low smoke halogen-free sheathed flame-retardant power cable and so on 2
Identification method of low smoke halogen-free flame retardant wire: skin burning method
Scald the insulating layer with an electric soldering iron
There should be no obvious depression
If there is a large depression, it indicates that the material or process used in the insulating layer is defective
Or barbecue with a lighter
Under normal circumstances, it should not be easy to ignite
After burning for a long time, the insulation layer of the cable is still relatively complete, there is no thick smoke and pungent smell, and the diameter increases at the same time
If it is easy to ignite, it can be determined that the insulation layer of the cable does not use low smoke halogen-free material (it is likely to be polyethylene or cross-linked polyethylene)
If there is large smoke, it indicates that the insulating layer is made of halogen containing material
If the insulation surface falls off seriously and the diameter does not increase significantly after long-time combustion, it indicates that appropriate irradiation crosslinking process treatment has not been carried out 3
Identification method of low smoke halogen-free flame retardant wire: hot water immersion method
Immerse the wire core or cable in hot water at 90 ℃, and the insulation resistance will not drop rapidly under normal conditions and will remain at 0
1M & omega/ Above km
If the insulation resistance drops rapidly or even lower than 0
009m & omega/ Km, it indicates that it has not been treated by appropriate irradiation crosslinking process
(polyethylene or cross-linked polyethylene insulating materials are not applicable to this method, but can be identified by the method in Article 2 above) 4
Density comparison method for identification method of low smoke halogen-free flame retardant wire
The density of low smoke halogen-free material is higher than that of water
You can peel off a little insulating layer and put it into water
If it floats above the water surface, it must not be low smoke halogen-free material The above is the introduction of Xiaobian on the characteristics and identification methods of low smoke halogen-free flame retardant wires
After we understand the characteristics of low smoke halogen-free flame retardant wires, we even know this kind of wires
I hope the introduction of Xiaobian above can help you
Contacts
- Company Name
- Zhengzhou Yixian Cable Co., Ltd
- Name:
- Mr. Li Shijie
- Telephone
- 13103714944
Address
- Operational Address
- Wulikou Industrial Park, Guodian Town, Zhengzhou City, Henan Province
Find Similar Products By Category
premiumexporter.com温馨提示
本网页所展示的有关【Characteristics and identification method of low smoke halogen-free flame-retardant wire of Zhengzhou first cable Co., Ltd】的信息/图片/参数等由的会员【Zhengzhou Yixian Cable Co., Ltd】提供,由premiumexporter.com会员【Zhengzhou Yixian Cable Co., Ltd
】自行对信息/图片/参数等的真实性、准确性和合法性负责,本平台(本网站)仅提供展示服务,请谨慎交易,因交易而产生的法律关系及法律纠纷由您自行协商解决,本平台(本网站)对此不承担任何责任。您在本网页可以浏览【Characteristics and identification method of low smoke halogen-free flame-retardant wire of Zhengzhou first cable Co., Ltd】有关的信息/图片/价格等及提供【Characteristics and identification method of low smoke halogen-free flame-retardant wire of Zhengzhou first cable Co., Ltd】的商家公司简介、联系方式等信息。
在您的合法权益受到侵害时,请您致电,我们将竭诚为您服务,感谢您对premiumexporter.com的关注与支持!