Welcome !

Hangzhou Fuyang District Xindeng town ultrafiltration hardware business department

企业会员1YEAR

Hangzhou Fuyang District Xindeng town ultrafiltration hardware business department

Country:Nationwide,China

Business:Freeze dryer, adsorption dryer, precision filter, precision filter element, oil-water separator, degreaser, rear cooler, automatic drain

Central oxygen supply and exhaust antivirus device in hospital

PriceCN ¥588.00

Brand
Jiajie
Quantity
9999
Min. Order
1
Country
ZhejiangHangzhou,China
Recommended For You
品牌:
Jiajie
Central oxygen supply and exhaust antivirus device in hospital
4
Domestic brand filter elements are all substitutes for the original brand filter elements produced by our company, and their filter materials are products of HV company imported from Germany with the registered trademark of “ Jiajie ” Cards
Other brands involved in the company have no brand significance, but are only used as a reference for product model and customer selection
Imported filter elements and filters are imported with original packaging and have anti-counterfeiting marks
Our company has been OEM various styles of compressed air precision filter elements for major domestic enterprises for a long time
Welcome to inquire!
I   Product introduction
Medical vacuum system is widely used in medical and surgical operations to provide timely and reliable attraction power
In the environment, the increasingly sensitive to pollution and the protection against infection make filtration the core of these systems

  Vacuum system filtration has been widely used
No inlet filtration will damage the vacuum pump and destroy the vacuum degree,   Cause pollution and equipment stop working
The pollutants in the inlet pipeline include particles, dust, water vapor and other gases
Outlet emissions will also include particles, oil and harmful gases
Professional inlet and exhaust filters can effectively deal with these pollutants
Professional sterilization and filtration are dangerous for a large number of bacteria in the pipeline and outlet of any vacuum system
In order to protect the health of patients, medical staff, other service personnel and people, it has been proposed to install and maintain bacterial filters before
Failure to install or maintain a sterilizing filter in front of the vacuum pump will not only damage the vacuum pump, but also make the vacuum pump a source of bacterial pollution
The proper temperature and humidity of the vacuum pump is the growth of bacteria, which will cause risks to the vacuum pump itself from a technical point of view, leading to the replacement of the vacuum pump

  Performance of vacuum sterilization filter
According to bs3928:1969 test method, when the filtration efficiency exceeds 99
995% and the vacuum degree is 630mbar, the differential pressure loss does not exceed 30mbar
  There are instructions for filter replacement and treatment
  As2896 medical gas system describes the inlet filter as follows: the medical inlet filter should be a bacterial filter, with appropriate size so that the pressure difference does not exceed 3
5kpa, and the filter element should be iso8573
1  0
01μ M

  Regulations on sterilization filter in technical specification for medical gas engineering:
5
2
16 filter accuracy 0
01-0
2-mu; m
The filtration efficiency is 99
995%
Maintain the sterilizing filter and replace the filter element to prevent the system flow from being affected by excessive differential pressure

  The negative pressure sterilizing filter is mainly a large-area sterilizing filter element, with a quick installation structure, and the filtering accuracy is 0
22-mu; 0
01μ, The bacteria and various bacteriophages can be removed by 99
995% by using 121 ⌀ net steam for periodic sterilization
It is a link in the medical center suction system industry, and the sterilization filter is the choice of negative pressure air sterilization
The sterilizing filter is made of 304 or 316L stainless steel shell, which is polished with mirror to ensure that there is no dead corner of parasitic bacteria
The filter element of the sterilization filter adopts the steam sterilized PTFE folding filter element
The filter element has the characteristics of high pressure resistance, high temperature, hydrophobicity and high density

II   Installation and configuration
1 during installation, connect the pipes according to the air inlet and outlet labels on the filter
Otherwise, reverse installation of the inlet and outlet will affect the filtering effect
In order to facilitate use, replacement and maintenance, the filter should be installed according to the pipeline shown in the figure below

 
Hangzhou Jiajie Electromechanical Equipment Co
, Ltd
Address: No
1191, Linding Road, Jianggan District, Hangzhou (Building B, jiadewei Industrial Park)   Editor: 310021
Address network: http://www
chao-lv
com/ Person in charge: Zhu Xiaoping phone: 0571-28811100
True story: 0571-85142370  Manipulator: 13588388654 
Mail: jjzxp0707@163
com
Contacts
Company Name
Hangzhou Fuyang District Xindeng town ultrafiltration hardware business department
Name:
Mr. Zhu Xiaoping
Q Q
2729554936
Telephone
0571-28811100
Mobile
15757184393
Address
Operational Address
Changdong village, Xindeng Town, Fuyang District, Hangzhou
Find Similar Products By Category
premiumexporter.com温馨提示

本网页所展示的有关【Central oxygen supply and exhaust antivirus device in hospital】的信息/图片/参数等由的会员【Hangzhou Fuyang District Xindeng town ultrafiltration hardware business department】提供,由premiumexporter.com会员【Hangzhou Fuyang District Xindeng town ultrafiltration hardware business department 】自行对信息/图片/参数等的真实性、准确性和合法性负责,本平台(本网站)仅提供展示服务,请谨慎交易,因交易而产生的法律关系及法律纠纷由您自行协商解决,本平台(本网站)对此不承担任何责任。您在本网页可以浏览【Central oxygen supply and exhaust antivirus device in hospital】有关的信息/图片/价格等及提供【Central oxygen supply and exhaust antivirus device in hospital】的商家公司简介、联系方式等信息。

在您的合法权益受到侵害时,请您致电,我们将竭诚为您服务,感谢您对premiumexporter.com的关注与支持!