reciprocating unit | diaphragm pump |
Transmission medium | clean water pump |
NPSH | 3 (m) |
suction diameter | 8*3 (mm) |
discharge diameter | 8*3 (mm) |
voltage | 220 (V) |
P146 series electromagnetic metering pump has a flow of 2
2L and a pressure of 17
3bar
Milton Luo electromagnetic metering pump series
LMI electromagnetic metering pump has 7 series including P, a, B, C, e, h and J5
According to the flow, pressure, explosion-proof
The corresponding series of metering pumps are required for power supply and automatic control
control mode
9-programmable high-precision microprocessor control, with liquid crystal display and four touch film keys, receiving external 4~20ma signals
(programmable) or pulse signal (passive reed switch, transistor or optocoupler contact) control
The input pulse can be multiplied
Or division and batch accumulation
Manual / automatic mode is optional
With digi pulse flow monitor, convection can be realized
Alarm and monitor the quantity
7 receive external pulse signal (passive reed switch, transistor or optocoupler contact) for control
Manual / automatic mode is optional
with
MP series control module can receive 4~20ma control signal or multiply / divide the received pulse signal
1-manually adjust the stroke length and stroke frequency (manual double adjustment)
Frequency adjustable range: p12 □, P13 □ 0~60spm
The rest are 0~100spm, 0-fixed stroke frequency, and manually adjust the stroke length
Characteristics of Milton Luo metering pump
Over pressure automatic protection, no need for safety valve
Wide flow regulation range, up to 1000:1
It is convenient for external automatic control and directly responds to external 4~20ma signals and pulse control signals
The moving parts are simple (simple is best principle), without lubrication and rotation
And transmission parts, high reliability
Modular structure, easy replacement of components, no welding
Fully sealed shell, IP65 protection grade, glass fiber reinforced PP material
Low power consumption, suitable for 25~66hz power supply
Equipped with direct source power supply (battery powered)
The capacity series of Milton Luo metering pump is detailed in the pump selection table of each series
The power plug
1-----120VAC
2 --------- 240VAC, USA plug
3 --------- 220VAC, DIN plug
5 --------- 240VAC UK plug
6-----240VAC Aust
/ NZ plug
7 --------- 220VAC Swiss plug
Note: ① Select power code 6 in Chinese Mainland, which is suitable for national standard socket
②
E series is delivered without power cord and plug, and the power code can only be 1 and 2
For pump head code y, please refer to the model selection table control attachment - pulse sender 26006
It is used for adding or expanding the capacity of electromagnetic metering pumps for a variety of chemicals, and sends control signals to multiple LMI electromagnetic metering pumps
It can control up to 10 pumps at the same time
When controlling the stroke frequency of the main pump, the other subordinate pumps will remain synchronously controlled
Therefore, up to 10 chemicals can be added at the same time
The proportional value between pumps can be preset
● cable: 3M ● switching capacity: 0
1A
● inductive load: 5W, 0
1a/230vac, 0
2a/28vdc
● resistive load: 8W, 0
5a/115vac or DC control accessories MP series electromagnetic metering pump control module
Function: when P7, a7, B7, C7 series are selected, and the external control input signal source is the following ①, ②, ③ types,
MP series control module is required
Power supply: 15Vdc (can be provided by electromagnetic metering pump) protection grade: IP65 input
Impedance: 100 ohm (mp-100) Milton Luo metering pump function
Make the stroke frequency of the metering pump directly respond to the external 4-20mA signal source to control the dosage  
Multiply and subtract the input pulse signal to adjust the stroke frequency of the metering pump in a proportional manner
Multiply the input pulse signal to adjust the stroke frequency of the metering pump in a proportional manner
The stroke frequency (0~100 times / min) of the metering pump can be remotely and externally controlled from 3 meters away and displayed digitally
Input signal source
① 4-20mA DC current signal
② High frequency pulse (flowmeter pulse output) (> 100 times / minute)
③ Low frequency pulse (flowmeter pulse output) (<100 times / min) digi plusetm flow monitor is used to monitor the pulsating flow of electromagnetic metering pump, for very low flow or no flow
The situation can send an electrical signal and connect to the remote counter or other receiving equipment
Fm-300: 0
5~16ml/ stroke, adjustable QM ax=95l/h
FM-200: 0
05~5
0ml/ stroke, adjustable QM ax=30l/h
Contact capacity: 36vac/dc, 100mA
Wall mounting bracket and flushing mask of metering pump: transparent plastic, used for LMI a, B, C series electromagnetic metering pumps, to prevent water splashing into the pump when flushing with water
Bracket: suitable for wall mounted installation of LMI series electromagnetic metering pumps, light and convenient
Material: PE
Stroke frequency: m ax 100spm
Pulse width: Min 15ms
Working pressure: Max 1
0MPa
Material: UHMW PE
'
Tel: 15221295669 Ma Xiang