Product specs

CategoryTransformers
Unitset
AC Recovery Level10mA 15mA
AC Trip ThresholdMin: 12.5mA Typ.: 15mA Max: 17.5mA Min: 18mA Typ.: 22.5mA Max: 27mA
Accuracy Grade1.0G
Ambient Operation Temperature Range40 °C-85 °C
ApplicationElectrical and power distribution
Capacity0.500kg
CategoryElectrical Engineering
AvailabilityInquiry required
Updated2026-05-05

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Electrical Engineering. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

Home Electrical & Electronics Sensor Current Sensor Residual Current Detection DC6ma AC20mA/30mA Leakage Current Sensor Zda13 US$ Piece ( ) Start Order Request Still deciding? Get samples of $ ! US$ 4.49/Piece Order Samp

Residual | Applications and Buyer Notes

Residual is organized as a sourcing-ready Electrical Engineering reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time q

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
TransformersBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
AC Recovery Level
10mA 15mABased on visible page data; confirm exact value in the RFQ.
AC Trip Threshold
Min: 12.5mA Typ.: 15mA Max: 17.5mA Min: 18mA Typ.: 22.5mA Max: 27mABased on visible page data; confirm exact value in the RFQ.
Accuracy Grade
1.0GBased on visible page data; confirm exact value in the RFQ.
Ambient Operation Temperature Range
40 °C-85 °CBased on visible page data; confirm exact value in the RFQ.
Application
Electrical and power distributionBased on visible page data; confirm exact value in the RFQ.
Capacity
0.500kgBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

RFQ Preparation Notes

Residual Current Detection DC6ma AC20mA/30mA Leakage Current Sensor Zda13 can be used as an RFQ preparation reference after reviewing the original product description, images, and specification table.

Use the inquiry form to add application context, quantity, destination, delivery timing, required standards, and customization constraints. Price status: Quote on request; quantity reference: Quantity by inquiry; lead time: Lead time by inquiry.

Key specifications

CategoryTransformers
Unitset
AC Recovery Level10mA 15mA
AC Trip ThresholdMin: 12.5mA Typ.: 15mA Max: 17.5mA Min: 18mA Typ.: 22.5mA Max: 27mA
Accuracy Grade1.0G
Ambient Operation Temperature Range40 °C-85 °C
ApplicationElectrical and power distribution
Capacity0.500kg
CategoryTransformers
CertificationRoHS
ColorBlue
CustomizationAvailable
CustomizedCustomized
DC Recovery Level3mA 3mA
DC Trip ThresholdMin.: 3.5mA Typ.: 4.5mA Max.: 5.5mA Min.: 3.5mA Typ.: 4.5mA Max.: 5.5mA
Feature Highlightsdigital, precision
Frequency RangeDC ~ 2kHz
IP Rating00
Input Pin High Level coltageMin.: 2.5V
Input Pin Low-Level VoltageMax.: 0.8V
Input Pin Voltage RangeMin.:-0.3V Max.: 5.5V
Matched Termspower supply, transformer
MaterialPlastic
Maximum Primary Conductor Voltage440V
Maximum Primary Current48A RMS
Model NO.ZDA13
OriginChina
Output20mA/30mA
Output Signal TypeAnalog Output
PWMOUT vs DC differential current ratio3.33%/mA
Power Supply VoltageMin.: 4.8V Typ.: 5V Max.: 5.2V
Product TitleResidual Current Detection DC6ma AC20mA/30mA Leakage Current Sensor Zda13
Production ProcessInjection
Rated Input6mA
Refund policyClaim a refund if your order doesn't ship, is missing, or arrives with product issues.
Response TimesCompliant with IEC62752:2016
Shipping Cost.
SpecificationDC6mA AC20mA/30mA
Supply CurrentTyp.: 16mA
Supply Voltage5V
Temperature40°c
TrademarkYHDC
Transport PackageCarton
TypeHall Type
US$2.99-4.491 Piece ( )
Voltage5v
Weight30g

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

PremiumExporter related sourcing paths

Related categories PremiumExporter related paths

Industrial Pumps

Switchgear and Breakers

Filling and Sealing Machines

Related solutions PremiumExporter related paths

PremiumExporter procurement phrases

PremiumExporter related product samples