M017 AN Series Vertical Textile Flammability Test | RFQ Sourcing Details
Laboratory Instruments · Quote on request
This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.
Quote on requestProduct specs
Buyer's Digest
Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Laboratory Instruments. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.
Original product description
The M017 AN series is a semi-automatic vertical flammability test chamber for laboratory evaluation of woven fabrics, knitted fabrics, coated products, and laminated products. A specimen is mounted vertically inside the chamber and exposed from below to a controlled flame.
The operator records afterflame time, smoldering time, and damaged length to assess flammability behavior. The series includes M017 AN-1, M017 AN-2, and M017 AN-3 configurations. Listed standards across the series include CFR 1615, CFR 1616, GB/T 5455, ASTM D6413, and CALIF TB-117.
The broader also references FAR 25.853, NFPA 701 small scale, CPAI-84, CAN/ULC S109 small flame, UL 214 small flame, and CA Title 19, but explicitly states that users must confirm the required test standard. Model selection is therefore essential before procurement.
The chamber uses brushed stainless-steel plate and has a stated internal test space of 329 × 329 × 767 ±2 mm. The complete instrument is listed at 630 × 400 × 860 mm and approxima ±2 mm, and flame application time is adjustable up to 12 seconds.
Afterflame and smoldering counters cover 0.1–999.9 seconds with 0.1-second resolution. Buyers should confirm the exact M017 AN configuration, required standard, nozzle diameter and angle, specimen-holder format, supplied weights, gas connection requirements, and local electrical compatibility.
They should also verify whether CE documentation is required for the order and whether an optional third-party ISO 17025 calibration certificate is needed.
Calibration scope, certificate issuer, installation needs, training charges, consumables, spare-parts coverage, packing dimensions, and final shipping weight should be agreed in the purchase specification.
M017 | Applications and Buyer Notes
M017 is organized as a sourcing-ready Laboratory Instruments reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time quest
Applications
- Initial shortlist building for related product or supplier options.
- Specification and application fit review before bulk purchasing.
- Category, keyword and detail-page comparison before sending an RFQ.
Key specifications
- Category
- Laboratory InstrumentsBased on visible page data; confirm exact value in the RFQ.
- Unit
- setBased on visible page data; confirm exact value in the RFQ.
- Operation
- Semi-automaticBased on visible page data; confirm exact value in the RFQ.
- Burning gas
- Propane or butaneBased on visible page data; confirm exact value in the RFQ.
- Flame height
- 40 ±2 mmBased on visible page data; confirm exact value in the RFQ.
- Gas pressure
- 17.2 ±1.7 kPa, adjustableBased on visible page data; confirm exact value in the RFQ.
- Model series
- M017 AN;configurations M017 AN-1, M017 AN-2, and M017 AN-3Based on visible page data; confirm exact value in the RFQ.
- Power supply
- Single-phase AC 220 V, 50 Hz, 100 WBased on visible page data; confirm exact value in the RFQ.
Buyer tips
- State quantity range and split-delivery needs before price comparison.
- Add certification, material or inspection standards when they affect acceptance.
- For time-sensitive projects, include target arrival date and destination.
- For special applications, describe operating condition, installation environment and duty cycle.
FAQ
What should buyers confirm first?
Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.
Can buyers inquire when specs are incomplete?
Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.
How should this listing be evaluated?
Check title, category, specifications and related keywords against the actual sourcing requirement.
Source mix: ugc
Key specifications
Product sourcing keywords
These terms come from the title, visible copy and specifications, and link into matching aggregate pages.
Continue from this detail page into sourcing structure
These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.
This URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Cleanroom And Lab Furniture categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Laboratory Instruments categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Sample Preparation And Consumables categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Testing And Measurement Equipment categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Procurement sourcing pathThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 0 001g High Accuracy Laboratory Grade Analytical Balance For Gold Jewelry Measurement Analytical BThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Cleanroom Monitoring Systems sourcing pathThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Cleanroom Product Suppliers sourcing pathThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Digital Inspection Microscopes sourcing pathThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 16500rpm High Speed Capillary Hematocrit Centrifuge For Hospital Medical Use Hematocrit CentrifugeThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Advanced Cup Temperature Shock Test Chamber For Gas ImpactThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Aoda 2700 Nir Spectrometer For Food Feed And Grain AnalysisThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path CompanyThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
LabInstSource related sourcing paths
Sample Preparation and Lab Basics
LabInstSource procurement phrases
LabInstSource related product samples
We are a manufacturer specializing in the R&D of laboratory electric heating equipment. Our process is unique worldwide,...
Sample Preparation and Lab Basics Semi-Exhaust Type Biological Safety Cabinet Machine Medical Equipment - Medical Equipment and MedicaSemi-exhaust type biological safety cabinet school laboratory 1.Description The biosafety cabinet protects both human sa...
Sample Preparation and Lab Basics Etcolabs PP Fume Hood - Compliant with En 14175 Ashrae mm - 2026 Fume Hood, En 14175 FuIn the domain of laboratory safety, our fume hoods stand as indispensable protectors, catering to the rigorous demands o...
Sample Preparation and Lab Basics Laboao InUsing American Marlow semiconductor refrigeration sheet, the maximum temperature change rate is more than 5 degrees per ...
Sample Preparation and Lab Basics Erun-Sp9-B6 High-Accuracy Turbidimeter Laboratory-Grade Tool for Industrial Water Quality TestingIntroduction This instrument features 16 channels for the optical method and can measure over 60 parameters, as well as ...
Sample Preparation and Lab Basics Cordial Lab 5-5000ml Borosilicate 3.3 Glass Low Form Beaker for Lab Use - Glass Beaker and Low Form: With Spout and graduations 4. Color: Clear-to-read white enamel graduated scale. 2) Borosilicate tubing made and machi...