PowerGridSourceSwitchgear, transformers, breakers, metering devices, and power distribution components for global buyers.
Three-Phase Ester-Oil Pad-Mounted Transformer, 5–10 MVA, Up to 34.5 kV
Pad Mounted Transformers

Three-Phase Ester-Oil Pad-Mounted Transformer, 5– | RFQ Sourcing Details

Pad Mounted Transformers · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryPad Mounted Transformers
Unitset
Frequency50/60 Hz
Impedance3–10% or customized
Product typeThree-phase, two-winding pad-mounted transformer
Feed arrangementLoop or radial
HV tapping range±2 × 2.5% or customized
Insulation classA/E for HV/LV
CategoryPad Mounted Transformers
AvailabilityInquiry required
Source date2026-07-20

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Pad Mounted Transformers. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

This three-phase pad-mounted transformer is designed for medium-voltage power distribution projects requiring a compact, oil-immersed unit with configurable electrical ratings.

The documented capacity range is 5–10 MVA, with high-voltage options of 3.3, 4.16, 13.2, 13.8, and 34.5 kV and low-voltage options of 0.23, 0.24, 0.4, and 0.48 kV. Custom voltage configurations are listed as available. For ester-fluid configurations, the stated cooling methods are KNAN and KNAF.

Mineral-oil ONAN and ONAF configurations are also listed. The transformer is specified for 50 or 60 Hz service, with two windings, loop or radial feed arrangements, and three-limb or five-limb core options. Listed vector-group choices include Dyn11, Yy0, Dd0, and YNd11.

The stated impedance range is 3–10%, while the high-voltage tapping range is ±2 × 2.5%;customized values are offered for both parameters. Available winding materials are listed as aluminum or copper, and the core-material choices are silicon steel or amorphous alloy.

Other stated parameters include A/E insulation classes, off-load tap changing, 60/65 K temperature-rise options, ambient operation from -25°C to +50°C, and altitude below 3,000 m. The product information identifies IEC, IEEE, ANSI, UL, and KEMA references and lists CE, UL, and KEMA product certifications.

Buyers should obtain the applicable certificates and test documentation for the exact ordered design rather than assuming every configuration carries every listed approval.

The transformer is presented for distribution duties including power grids, data centers, wind farms, solar-energy facilities, industrial areas, residential neighborhoods, commercial centers, factories, mines, harbors, ports, and grid-renovation projects.

Because the available ratings and construction choices cover multiple configurations, final suitability depends on an approved project-specific specification.

Before procurement, confirm the required capacity, primary and secondary voltages, vector group, system frequency, impedance, tapping range, feed arrangement, winding and core materials, insulation levels, cooling mode, fluid type, temperature-rise limit, ambient conditions, and installation altitude.

Buyers should also define required accessories, monitoring functions, protection equipment, enclosure arrangement, terminal interfaces, applicable standard edition, certification scope, routine and type tests, drawings, losses, sound limits, dimensions, mass, delivery schedule, warranty, and commissioning responsibilities.

These items are not fully established for a specific supplied unit by the available product facts.

Three-Phase | Applications and Buyer Notes

Three-Phase is organized as a sourcing-ready Pad Mounted Transformers reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-t

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Pad Mounted TransformersBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Frequency
50/60 HzBased on visible page data; confirm exact value in the RFQ.
Impedance
3–10% or customizedBased on visible page data; confirm exact value in the RFQ.
Product type
Three-phase, two-winding pad-mounted transformerBased on visible page data; confirm exact value in the RFQ.
Feed arrangement
Loop or radialBased on visible page data; confirm exact value in the RFQ.
HV tapping range
±2 × 2.5% or customizedBased on visible page data; confirm exact value in the RFQ.
Insulation class
A/E for HV/LVBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryPad Mounted Transformers
Unitset
Frequency50/60 Hz
Impedance3–10% or customized
Product typeThree-phase, two-winding pad-mounted transformer
Feed arrangementLoop or radial
HV tapping range±2 × 2.5% or customized
Insulation classA/E for HV/LV
Temperature rise60/65 K options
Ester-oil coolingKNAN/KNAF
Core configurationThree limbs or five limbs
Low-voltage options0.23, 0.24, 0.4, or 0.48 kV;customizable
Mineral-oil coolingONAN/ONAF
Tap-changing methodOff-load tap changing
High-voltage options3.3, 4.16, 13.2, 13.8, or 34.5 kV;customizable
Core-material optionsSilicon steel or amorphous alloy

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

PowerGridSource related sourcing paths

PowerGridSource procurement phrases

PowerGridSource related product samples

Supplier profile

PowerGridSource Imported Supplier Pool
主营:Pad Mounted Transformers

View full profile >