Product specs

CategoryTransformers
Unitset
1 min power frequency withstand voltageKV 42/48 42/48
5 min zero gauge rated power frequency withstand voltageKV 24 24
Ambient Temperature35c-+40c
ApplicationElectrical and power distribution
CategoryTransformers
Closing the same periodms
CategoryElectrical Engineering
AvailabilityInquiry required
Updated2026-05-05

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Electrical Engineering. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

Home Electrical & Electronics Switch Other Switches Fluorinated Gas Load Break Switch Fln48 US$500.00-1,000.00 1 Piece

Fluorinated | Applications and Buyer Notes

Fluorinated is organized as a sourcing-ready Electrical Engineering reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-tim

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
TransformersBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
1 min power frequency withstand voltage
KV 42/48 42/48Based on visible page data; confirm exact value in the RFQ.
5 min zero gauge rated power frequency w
KV 24 24Based on visible page data; confirm exact value in the RFQ.
Ambient Temperature
35c-+40cBased on visible page data; confirm exact value in the RFQ.
Application
Electrical and power distributionBased on visible page data; confirm exact value in the RFQ.
Closing the same period
msBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

RFQ Preparation Notes

Fluorinated Gas Load Break Switch Fln48 can be used as an RFQ preparation reference after reviewing the original product description, images, and specification table. Use the inquiry form to add application context, quantity, destination, delivery timing, required standards, and customization constraints.

Price status: Quote on request; quantity reference: Quantity by inquiry; lead time: Lead time by inquiry.

Key specifications

CategoryTransformers
Unitset
1 min power frequency withstand voltageKV 42/48 42/48
5 min zero gauge rated power frequency withstand voltageKV 24 24
Ambient Temperature35c-+40c
ApplicationElectrical and power distribution
CategoryTransformers
Closing the same periodms
CustomizationAvailable
FLN48-12D/T630-20FLN48-12D/T125-50
Fuse strikes the output energyJ 1±0.5
Fuse typeXRNT-12KV/125A
ItemUnit Parameter
Lighting impulse withstand voltage(PEAK)KV 75/85 75/85
Main circuit tesistanceμΩ
Matched Termselectrical equipment, circuit breaker, power supply
Mechanical lifeTime 5000/ /2000
Model NO.FLN48
OriginChangzhou, Jiangsu, China
Product TitleFluorinated Gas Load Break Switch Fln48
Rated active load breaking currentA 630
Rated cable charging breaking currentA 10 10
Rated closed-loop breaking currentA 630
Rated currentA 630 125
Rated dynamic current(peak)KA 50/50 50/50
Rated frequencyHz 50 50
Rated short circuit breaking currentKA 50
Rated short circuit closing currentKA 50/50 125/50
Rated thermal stability current(peak)KA 20/20 20/20
Rated transfer currentA 1750
Rated voltageKV 12 12
SF6 Gas pressure (relative pressure at 20ºC)bar 0.4 0.4
Seismic Capacity8 Degree Level
Temperature40°c
The insulation distance betweent the live body and the groundmm >=125 >=125
TrademarkDECHUN
US$500.00-1,000.001 Piece ( )
Voltage12kv

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

PremiumExporter related sourcing paths

Related categories PremiumExporter related paths

Industrial Pumps

Switchgear and Breakers

Filling and Sealing Machines

Related solutions PremiumExporter related paths

PremiumExporter procurement phrases

PremiumExporter related product samples