PLCDriveHubPLC, HMI, sensors, drives, controllers, robots, and factory automation parts for global industrial buyers.
1756-OV16E Control. Logix 16-Point Electronically Fused DC Sinking Output Module
Plc Modules

1756-OV16E Control. Logix 16-Point Electronically | RFQ Sourcing Details

Plc Modules · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryPLC Modules
Unitset
Module typeElectronically fused sinking DC output module
Output count16 points
Surge current2 A for 10 ms per point, recurring every 2 seconds
Catalog number1756-OV16E
Pilot-duty rating1 A, DC-13/SR
Voltage designation12–24 V DC sink
CategoryPlc Modules
AvailabilityInquiry required
Source date2026-07-21

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Plc Modules. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

The 1756-OV16E is a 16-point electronically fused sinking DC output module for a ControlLogix chassis. Its listed operating range is 10–30 V DC, with up to 1 A per output point and 8 A aggregate module current at 60 °C.

1756-OV16E | Applications and Buyer Notes

1756-OV16E is organized as a sourcing-ready Plc Modules reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time questions

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
PLC ModulesBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Module type
Electronically fused sinking DC output moduleBased on visible page data; confirm exact value in the RFQ.
Output count
16 pointsBased on visible page data; confirm exact value in the RFQ.
Surge current
2 A for 10 ms per point, recurring every 2 secondsBased on visible page data; confirm exact value in the RFQ.
Catalog number
1756-OV16EBased on visible page data; confirm exact value in the RFQ.
Pilot-duty rating
1 A, DC-13/SRBased on visible page data; confirm exact value in the RFQ.
Voltage designation
12–24 V DC sinkBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

RFQ Preparation Notes

1756-OV16E Control. Logix 16-Point Electronically Fused DC Sinking Output Module can be used as an RFQ preparation reference after reviewing the original product description, images, and specification table.

Use the inquiry form to add application context, quantity, destination, delivery timing, required standards, and customization constraints. Price status: Quote on request; quantity reference: Quantity by inquiry; lead time: Lead time by inquiry.

Key specifications

CategoryPLC Modules
Unitset
Module typeElectronically fused sinking DC output module
Output count16 points
Surge current2 A for 10 ms per point, recurring every 2 seconds
Catalog number1756-OV16E
Pilot-duty rating1 A, DC-13/SR
Voltage designation12–24 V DC sink
Maximum signal delay1 ms in either direction
Maximum voltage loss700 mV DC at 1 A
Minimum load current2 mA per point
Operating temperature0–60 °C
Nominal OFF-to-ON delay75 μs
Nominal ON-to-OFF delay360 μs
Operating voltage range10–30 V DC
Maximum OFF-state leakage1 mA per point
Maximum power dissipation6.72 W at 60 °C
Maximum aggregate module current8 A at 60 °C
Maximum output current per point1 A at 60 °C

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

PLCDriveHub related sourcing paths

Related applications PLCDriveHub related paths

Robotic Picking And Inspection

Related solutions PLCDriveHub related paths

Plc Control Panel Procurement

Sensor And Drive Integration

PLCDriveHub procurement phrases

PLCDriveHub related product samples

Supplier profile

PLCDriveHub Imported Supplier Pool
主营:PLC Modules

View full profile >